83
Installation
6005770_a – 07.04.2021
EN
1.
1.
2.
2.
☞
Ensure that the gap for the guide rails is correct.
☞
Slide the parts from the protective grating sideways onto
the drive unit until the fastening holes are on top of each
other.
☞
Affix the protective grating by screwing the screws into
the thread adapter.
3.5.4
Install the device from outside
☞
Take note of how the wall fastening bracket is aligned:
y
Square mounting recess = top
y
Round mounting recess = bottom
☞
Align the wall fastening bracket to the centre of the
exhaust air duct.
☞
Determine the hanging position.
☞
Determine the locations of the fastening points and mark
them.
D
WARNING!
Risk of death due to explosions or electric shock!
Drilling through gas, water or electrical lines can lead to
hazardous situations.
☞
Ensure that there are no lines in the wall at the fastening
points.
Ø 6
☞
Drill the holes in the wall.
☞
Insert the wall plugs into the holes.
Summary of Contents for BMK-F 125