33
EN
Product information
6002948_a – 20.11.2019
2.
Product information
2.1
Product overview
The device provides additional functions for the cooker hood.
All of the device’s functions are controlled by the cooker
hood.
The device is used in extracted air mode and closes the
exhaust air duct. When it is switched on, the device’s front
flap opens. The device extracts the cooking vapours and
conveys it to the outside. After switching off, the device
switches off after a short time delay and the front flap is
closed.
When the front flap is closed, the exhaust air duct is sealed
and is insulated against sound and heat.
Observe the cooker hood’s instructions.
E
A
C
D
B
A Moving front flap
B Wall power supply connection
C Outlet for exhaust air duct
D Housing
E Connection for mains and control cables
2.2
Scope of delivery
A
B
C
E
D
I
H
G
F
A External fan BAL 150
B Front flap
C Mains and control cables, 5 m
D 12 volt wall power supply
E Nylon wall plugs, 10 mm
F M8 hanger bolt
G M8 hexagonal threaded sleeve
H Spacer sleeve
I Installation instructions