BENZING M1 – Fancier
INSTALLATION AND OPERATION
16
HB_BENZING-M1_ZUECHTER-E_13.doc
GANTNER Pigeon Systems GmbH
Figure
3.1 – Fancier System BENZING M1
When installing the device the following must be observed:
• First the lazer loft antennae (PLB) must be supplied with power. After this the
BENZING M1 will be connected.
• In a fancier’s system the power supply unit must always be plugged into the
corresponding jack of the connection cable. The socket
on the BENZING M1
will not be used in this case, as power supply of the lazer loft antennae would be
impossible.
• After having plugged in the power supply unit the green LED display ‘Power
supply’ must light up (see figure 3.1). This indicates that the power supply is
correctly provided.
• Connection to the power mains should always be provided near the antennae.
• For the provision of power the included power supply unit should always be
used or a similar power supply unit of an equivalent type.
• When using the provided power supply unit only up to 3 loft antennae lazer 4
(PLB 765), 6 lazer 3 (PLB 475) or 10 lazer 1 (PLB 170) can be connected. For
information concerning the connection of more than three antennae please
contact your sales agent.
• Before plugging in the power supply unit please check if the installation
corresponds to the diagram 3.1. Make sure that before connecting the
BENZING M1 to the mains humidity has not found its way into the case of the
BENZING M1 and that the device is being operated according to the
conditions of use mentioned in 3.1.
!
DB-9 Antenna Plug
Power Supply Unit (1.5 A)