background image

1

TC707

bentrup TC707 sets a landmark in programme cont-
rollers for kilns providing fully intuitive man machine 
interface. 
Color of main display changes according to precise 
following the programme profile; the user interface 
of the TC707 is understood straight forward.
 
Continuous data logging of all relevant process data 
(CSV-format open by EXCEL) dumped on an USB-
Stick provides documentation of the temperature 
process as well as easy error tracking of process and 
kiln components.

Use the bentrup smartphone app to monitor your 
kiln from everywhere (via bentrup WebBox or Web-
browser extension). Configuration and technical di-
agnosis from remote allows fast and efficient custo-
mer support.

Data link is established via Bluetooth for reliable and 
communication in rough industrial environments.
TC707 is fitted with a real time clock providing data 
logging according to ISO900x as well as automatic 
programme launch (e.g. kiln is heat up to working 
temperature when norning shift starts and shut 
down during night or weekend).

 

TC707 expansion stages

Base model of TC707 is for 1 zone processes and 
fitted with 4 control outputs and one optional ana-
logue output (2 more control zones on request). 
Further expansions are available via the bentrup 
IO-Box (DIN rail mounting) holding up to 3 modules 
each (isolated electrical inputs / outputs etc.)

New PS3 modul measures actual power of up to 3 
phases. By comparing with initially recorded values 
TC707 allows ageing of heating elements as well 
as technical problems before quality issues emerge 
by excessive heating cycles. If PS3 is not installed 
TC707 estimates power by analyzing the heat up 
speed (SmartCheck).

TC707

Die TC707 markiert ein neue Familie Programmreg-
ler, die durch eine anwendungspezifische Mensch 
-Maschine Schnittstelle intuitiv zu bedienen ist. 
Die korrekte Verlauf des Ofenprogramms ist auch 
farblich sofort erkennbar, die Bedienfront des TC707 
ist klar und übersichtlich gegliedert.

Besonders die Aufzeichnung aller relevanten Pro-
zessdaten im CSV-Format (direkt in EXCEL zu öff-
nen) auf einem USB-Stick ermöglichen lückenlose 
Prozessdokumentation sowie Diagnose der Ofen-
technik in Sekunden.

Ebenso ist der TC707 über die bentrup App im 
Smartphone weltweit erreichbar (über bentrup Web-
Box oder Browser-Erweiterung). Hierüber sind auch 
Konfiguration und Tests des Anlagenbauers leicht 
möglich.

Die Anbindung hierzu erfolgt kontaktlos über Blue-
tooth zur Vermeidung von elektrischen Problemen.
Die TC707 ist mit einer Echtzeituhr ausgestattet, für 
ISO900x konforme Dokumentation und auch auto-
matische Programmstartfunktionen (z.B. automati-
sches Anfahren des Ofen zur Arbeitsbeginn).
 

TC707 Ausbaustufen

In der Grundversion regelt die TC707 einzonige Öfen 
mit bis zu 4 Schaltfunktionen und 1 Analogausgang. 
Über die bentrup IO-Box (DIN-Hutschienenmontage) 
sind die Ein/Ausgänge praktisch beliebig erweiter-
bar. Typische Anwendung sind 3-zonige Öfen.

Neu ist das PS3 Modul für die IO-Box, mit dem die 
tatsächliche Leistung von je 3 Ofenphasen real ge-
messen werden kann. Der TC707 vergleicht hier 
die gelernten Originalwerte und meldet frühzeitig 
Alterung, bevor Qualitätsverlust durch exzessive 
Aufheizraten entsteht. Auch ohne PS3 steht diese 
Funktion grundsätzlich zur Verfügung (Messung 
durch Aufheizrate).

Summary of Contents for TC 707

Page 1: ...1 Programmregler Programme Controller TC 707 Bedienungsanleitung Operating Instructions...

Page 2: ...current process manueller Test Konfiguration manual comissioning configuration USB Port f r Protokoll CSV Pro gramm bernahme und Event Log USB Socket for firing log pro gramme import and Eventlog Wer...

Page 3: ...issues emerge by excessive heating cycles If PS3 is not installed TC707 estimates power by analyzing the heat up speed SmartCheck TC707 Die TC707 markiert ein neue Familie Programmreg ler die durch ei...

Page 4: ...gestellt Dr cken Sie die Pfeiltaste nach rechts um die Endtemperatur des ersten Segments 400 C und nochmals nach Pfeiltaste rechts um die Haltezeit auf dieser Temperatur 10 Minuten einzustellen SEG R...

Page 5: ...uordnung Funktion ist vom Ofen abh ngig Im vorstehenden Programmbeispiel k nnte hiermit z B ein Ventilator aktiviert werden Pressing arrow right key again to enter segment 2 change value to SKIP highe...

Page 6: ...er aktuellen Temperatur Erforder liche Kriterien f r Programmabbruch und Warnun gen k nnen in der Konfiguration eingestellt werden PRG Programmes Fast choose programmes 1 to 9 by simply pressing the p...

Page 7: ...nach DWELL oder von DWELL zu RAM PE des n chsten Segments zu springen halten Sie die Taste Start Stopp f r 6 Sekunden gedr ckt SEG R A M P 3 1 0 3 seconds RUN HOLD 6 seconds RUN Starting a Process Pr...

Page 8: ...en sind kann von bentrup ein PUK angefordert werden bersicht auf n chster Seite Bei Auslieferung ist kei ne PIN gesetzt und alle Funktionen offen verf gbar Z1 Multizone Loop Applications TC707 in mult...

Page 9: ...ellung der Ursache ERR Event and Error Messages The TC707 reports abnormalities events and errors in the top line of the display The event or error code is also abbreviated depending on the configured...

Page 10: ...ob die Temperaturen sich noch an n hern andernfalls beendet der Regler das Segment trotzdem Emergency Exit ERR ERR ERR ERR ERR ERR ERR Monitored control loop deactivated due to tempera ture acquisitio...

Page 11: ...siehe weitere Angaben f r Details X Y IO Box X Modul Y Fehler USB Operation 1 Falscher Schl ssel ERR ERR ERR ERR ERR ERR ERR ERR ERR ERR ERR Controller restarts despite good supply voltage Check corre...

Page 12: ...Konfiguration greift tief in die Funktionit t des Reglers ein Ver nderungen k nnen Nichtfunktion oder auch Sch den an Brenngut und Ofen haben IDLE IDLE USB Data Exchange Hold down the key before inser...

Page 13: ...cheint deren Ver sionsummer bei start stop beginnt das Update Nach max 10 Sekunden zeigt completed das erfolg reiche Update an andernfalls erscheint Fehlercode Write event log The TC707 stores the rec...

Page 14: ...ei 100 Heizen Prozess 3 C pro 15 Minuten ansteigt sonst Err A4 OPT maximale Ber cksichtung Verz gerung 09 D PID 08 I PID 07 P PID 06 MaxTemp 03 TC type 02 TempUnit 01 Lang 11 HeatChk Configuration The...

Page 15: ...on figuration ausgew hlt Parameter 51 bis 55 Uhrzeit Stunden Minuten Sommerzeitumschaltung EU USA oder aus und Tag Monat Jahr Color change of the process temperature Direct color selection green or re...

Page 16: ...bernehmen der nderungen Erst durch Halten der Taste man inst f r 3 Sekunden werden die nderungen bernommen und die Kon figuration verlasssen Set a new PIN 0 digits means delete PIN 1 to 8 digits depen...

Page 17: ...from the ones shown below 6 5 4 1 2 3 7 HAN7D 3 1 7 4 11 8 14 12 1 5 4 3 2 a c b CPC14 HAN15D HAN7D HAN15D CPC14 PANEL 5 A1 8 1 mains supply L 2 B1 9 2 mains supply N 6 A3 14 4 control output heating...

Page 18: ...16 Operating Instructions TC 707 V0 1 C 2018 bentrup Industriesteuerungen Germany www bentrup com...

Reviews: