171 505 44  07-01

   

Gph

8

9

10

11

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

0,40

1,33

16

13

1,41

17

14

1,49

18

15

1,56

18

16

0,50

1,66

20

17

1,76

21

18

1,86

22

19

1,95

23

20

0,60

2,00

24

20

2,12

25

22

2,23

26

23

2,34

28

24

0,65

2,16

26

22

2,29

27

23

2,42

29

25

2,54

30

26

0,75

2,49

29

25

2,65

31

27

2,79

33

28

2,93

35

30

0,85

2,83

33

29

3,00

36

31

3,16

37

32

3,32

39

34

1,00

3,33

39

34

3,53

42

36

3,72

44

38

3,90

46

40

1,10

3,66

43

37

3,88

46

39

4,09

48

42

4,29

51

44

1,20

3,99

47

41

4,24

50

43

4,47

53

46

4,68

55

48

1,25

4,16

49

42

4,40

52

45

4,65

55

47

4,88

58

50

1,35

4,49

53

46

4,76

56

48

5,02

59

51

5,27

62

54

1,50

4,98

59

51

5,29

63

54

5,58

66

57

5,85

69

60

1,65

5,49

65

56

5,82

69

59

6,14

73

63

6,44

76

66

1,75

5,82

69

59

6,18

73

63

6,51

77

66

6,83

81

70

2,00

6,65

79

68

7,06

84

72

7,45

88

76

7,81

93

80

2,25

7,49

89

76

7,94

94

81

8,38

99

85

8,78

104

89

2,50

8,32

99

85

8,82

105

90

9,31

110

95

9,76

116

99

2,75

9,15

108

93

9,71

115

99

10,24

121

104

10,73

127

109

3,00

9,98

118

102

10,59

126

108

11,16

132

114

11,71

139

119

3,50

11,65

138

119

12,35

146

126

13,03

154

133

13,66

162

139

4,00

13,31

158

136

14,12

167

144

14,89

176

152

15,62

185

159

4,50

14,97

177

153

15,88

188

162

16,75

198

171

17,57

208

179

5,00

16,64

197

170

17,65

209

180

18,62

221

190

19,52

231

199

5,50

18,30

217

187

19,42

230

198

20,48

243

209

21,47

255

219

6,00

19,97

237

204

21,18

251

216

22,34

265

228

23,42

278

239

6,50

21,63

256

220

22,94

272

234

24,20

287

247

25,37

301

259

7,00

23,29

276

237

24,71

293

252

26,06

309

266

27,33

324

279

7,50

24,96

296

254

26,47

314

270

27,92

331

285

29,28

347

298

8,00

26,62

316

271

28,24

335

288

29,79

353

304

31,23

370

318

8,50

28,28

335

288

30,00

356

306

31,65

375

323

33,18

393

338

9,00

29,95

355

305

31,77

377

324

33,59

398

342

35,14

417

358

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

Burner with preheater

Consider that on preheating the oil quantity is reduced by 5-20% depending on.
-  Rise in temperature at the nozzle
-  Design of nozzle

-  Capacity (high capacity - small difference)

1(2)

Summary of Contents for B10E

Page 1: ...Providing sustainable energy solutions worldwide 178 013 03 2 2016 05 26 Installation and maintenance instruction B 10 E R...

Page 2: ......

Page 3: ...last tube 8 Ignition electrodes 9 Ignition cables 10 Ignition transformer 11 Electrical connection 12 Control box 13 Solenoid valve 14 Reset button 15 Pump 16 Motor 17 Indicating lamp preheater 18 Fan...

Page 4: ...nd nozzles recommended Flange A Flange B Flange C 89 5 21 10 5 130 150 89 5 26 130 150 12 89 5 12 130 150 12 The net caloriic value of 11 86 kWh kg for light oil has been used Burner tube Length of bu...

Page 5: ...btained If larger nozzlesareusedthepreadjustmentof the air volume must be increased Condensation in chimney A modern burner works with less excess air and often also with smaller nozzles than older mo...

Page 6: ...Retractthenozzleassemblyso farthattheignitioncablescanbe removed from the ignition electrodes 6 Remove the nozzle assembly 171 305 14 07 01 Service of burner head alt B 1 Slacken retaining screws 2 Re...

Page 7: ...olenoid valve X1 Plug in contact burner X2 Plug in contact boiler OIL BURNER CONTROL LOA21 LOA24 Wiring diagram If there is no plug in contact X2 on the boiler connect to the contact enclosed In case...

Page 8: ...urneroperationisinterruptedbymeansofthemainswitchorthe thermostat a new start takes place when the conditions in accordance with point 1 are fulilled The oil burner control cuts out A red lamp in the...

Page 9: ...ercial quality according to current standards On commissioning with an empty tube system the oil pump should not be run without oil for more than 5 min a condition is that the pump is being lubricated...

Page 10: ...cum stances the oil pressure falls below the set value andthevalveclosesagainstthe returnside R bymeansofthe diaphragm D andgoesintostarting position This can be remedied by Reducing the pump pressure...

Page 11: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Page 12: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Page 13: ...f magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocel...

Page 14: ...nnect a steel pipe 6 4 to the combustion chamber or the lue of the boiler Connect the rubber hose enclosed in the carton to the steel pipe and to the hose nipple marked on the pressure switch The pres...

Page 15: ...171 905 04 08 01 A1 Burner control S20 Pressure switch P1 Terminal strip B1 Ionisation electrode R1 Photoresistor 2 2...

Page 16: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...170 080 06 10 01...

Reviews: