Operating from the Keypad
+
Typing one of the two group codes (GROUP A, GROUP B)followed by EN-
TER will exclude the relative group. The reinclusion can take place in one
of the following ways:
re-entering the group code used for excluding;
automatically after the prefixed patrol time, if the PATROL ON option has
been activated (Patrol active);
disarming the system.
+
It must be observed that the exclusion of groups overlaps to that of each
single zone, therefore, if before the exclusion of groups a zone has already
been excluded, then on the reinclusion of the group it will remain the same.
The exclusions will however always be clearly indicated on the panel and
on the Control Keypads by means of the exclusion leds and on the key
readers by means of the lighting up of the group exclusion leds.
20
Alarm control panel
NORMA4
and
NORMA8