INSTALLATION

Mounting the Panel

The Panel should be located in a dry area, preferably near the mains
power source and incoming telephone line. 

Follow the installation instructions carefully, and refer to

 figure 1

.

Step 1

Unfasten the screws 

(1)

 and remove the front.

Step 2

Check for cable conduits and water pipes before drilling. Use the back box
as a drill pattern 

(

holes 

3)

.

Step 3

Attach the NCDUEVOX voice board 8 (if used).

Step 4

Pull the wires through the hole 

(10)

 and mount the back box.

Terminal board

Below is a description of the Main Unit terminal board, keypads and key
readers.

Ø

The 

Terminal 

column shows the terminal number and the identifier of each

terminal (in square brackets).

Ø

The 

DESCRIPTION 

column provides a description of each terminal.

The

 V

 column shows the voltage on the corresponding terminal. 

The 

I

 column shows the maximum current for each terminal. 

Where 

(1)

 or 

(2)

 is shown as the value in the

 I

 column refer to the footnote

below the terminal description table.

6

Security System Control Panel 

Academy8L

Summary of Contents for Academy8L

Page 1: ......

Page 2: ...eveloped and made according to the highest standards of quality reliability and performance adopted by BENTEL SECURITY srl Installation of the control panel must carried out strictly according to the...

Page 3: ...TABLE OF CONTENTS PARTS 5 The Main Unit 5 INSTALLATION 6 Mounting the Panel 6 Terminal board 6 Power supply connection 7 Open Panel 8 A Typical System 9 NCDUEVOX voice board 12 3...

Page 4: ...Figure 1 Parts 4 Security System Control Panel Academy8L...

Page 5: ...ge 26 9 Connector for the 3 A switching power supply BAQ35 or BAW35 optional 10 3 holes for wires 40 mm 11 Mains connection terminals 230 V 10 150 mA 12 Housing for 13 8 V 7 Ah standby battery optiona...

Page 6: ...d 8 if used Step 4 Pull the wires through the hole 10 and mount the back box Terminal board Below is a description of the Main Unit terminal board keypads and key readers The Terminal column shows the...

Page 7: ...atus voltage on terminal 13 8 2 37 N Terminal for self powered sirens Standby status voltage on terminal Alarm status terminal open 13 8 1 34 35 36 NC COM NO Voltage free alarm relay contacts Standby...

Page 8: ...will supply power during mains failure Mains failure will be signalled as follows MAIN LED on the Panel will go OFF TROUBLE LED on the Control Keypad will go ON Activation of one of the auxiliary out...

Page 9: ...ar sensor to line L1 Connection of three fire sensors to line L8 Tamper line connection Connection of additional devices Keypad and Key reader to the BPI bus Please note Line L1 must be programmed as...

Page 10: ...Figure 2 A Typical System...

Page 11: ...INSTALLATION 11...

Page 12: ...Step 3 When the NCDUEVOX is properly attached complete the connections then power the Panel and record the alarm messages as per the instruc tions in the INSTALLATION MANUAL The optional OmniaVox MS...

Reviews: