PARTS

The table below provides a brief description of each part (the numbers in
boldface refer to the parts illustrated in the

 figure 1

), and the meaning of

the 

ON / OFF 

status of  each indicator 

LED

.

PARTS

DESCRIPTIONS

1

4 screws

2

5 Indicator LEDs

3

4 holes (Ø 5 mm)

4

NormVox2 voice board connector

5

Protection fuse for sensor and auxiliary power supply (250 V - 5 A)

6

Protection fuse against polarity inversion on battery  (250 V - 8 A)

7

DB9 connector for PC connection via serial cable

8-8a

Tamper microswitch; 8a optional (see Installation Manual page 26)

9

Connector for the 3 A switching power supply BAQ35 or BAW35
(optional)

10

3 holes for wires (Ø40 mm)

11

Mains connection terminals (230 V~ 

 ±

10% / 150 mA)

12

Housing for 13.8 V / 7 Ah standby battery (optional)

13

Service mode jumper. Connection of this jumper will disable the Alarm
outputs  for  maintenance purposes.

14

Battery connectors

15

Firmware Release: to be communicated to Service dealer

LEDs

STATUS

ON:  

OFF:

Panel powered from mains
Mains failure----Panel powered by the battery

OFF:

ON:

Battery 

OK

Battery low or battery trouble

OFF:

ON:

Fuse 

intact (power to sensors)

Fuse

 5 

blown

OFF:

ON:

Communicator in standby status: telephone line free
Telephone line engaged by the communicator

OFF: 

ON:

Communication bus 

OK

Communication bus trouble

PARTS

5

Summary of Contents for Academy8L

Page 1: ......

Page 2: ...eveloped and made according to the highest standards of quality reliability and performance adopted by BENTEL SECURITY srl Installation of the control panel must carried out strictly according to the...

Page 3: ...TABLE OF CONTENTS PARTS 5 The Main Unit 5 INSTALLATION 6 Mounting the Panel 6 Terminal board 6 Power supply connection 7 Open Panel 8 A Typical System 9 NCDUEVOX voice board 12 3...

Page 4: ...Figure 1 Parts 4 Security System Control Panel Academy8L...

Page 5: ...ge 26 9 Connector for the 3 A switching power supply BAQ35 or BAW35 optional 10 3 holes for wires 40 mm 11 Mains connection terminals 230 V 10 150 mA 12 Housing for 13 8 V 7 Ah standby battery optiona...

Page 6: ...d 8 if used Step 4 Pull the wires through the hole 10 and mount the back box Terminal board Below is a description of the Main Unit terminal board keypads and key readers The Terminal column shows the...

Page 7: ...atus voltage on terminal 13 8 2 37 N Terminal for self powered sirens Standby status voltage on terminal Alarm status terminal open 13 8 1 34 35 36 NC COM NO Voltage free alarm relay contacts Standby...

Page 8: ...will supply power during mains failure Mains failure will be signalled as follows MAIN LED on the Panel will go OFF TROUBLE LED on the Control Keypad will go ON Activation of one of the auxiliary out...

Page 9: ...ar sensor to line L1 Connection of three fire sensors to line L8 Tamper line connection Connection of additional devices Keypad and Key reader to the BPI bus Please note Line L1 must be programmed as...

Page 10: ...Figure 2 A Typical System...

Page 11: ...INSTALLATION 11...

Page 12: ...Step 3 When the NCDUEVOX is properly attached complete the connections then power the Panel and record the alarm messages as per the instruc tions in the INSTALLATION MANUAL The optional OmniaVox MS...

Reviews: