![Bentel Security Academy 4 Programming Manual Download Page 5](http://html1.mh-extra.com/html/bentel-security/academy-4/academy-4_programming-manual_2735350005.webp)
PROGRAMMING FROM KEYPAD
For in-detail information on the following parameters and options refer to the
"PROGRAMMING"
chapter.
All the control panel parameters can be programmed from the keypad.
Only the
INSTALLER PIN
and
MAIN
USER PINs
can access the program-
ming phase.
+
The control panel will be
out of service
(alarm outputs disabled) during
the programming phase.
Restrictions
The Installer can program all the control panel parameters, with the excep-
tion of Code PINs 1 through 23.
A
Main User Code PIN
can change all
User, Duress and Patrol Code
PINs
enabled on the group of partitions it controls (see below).
CODE No.
TYPE
ASSIGNED
PARTITIONS
Code1
MAIN USER
1
-
3
-
4
Code2
MAIN USER
2
-
3
Code3
USER
1
- 3
Code4
USER
4
Code5
USER
3 - 4
Code6
PATROL
2
Code7
DURESS
3
Code8
USER
2 - 3
In the example above
MAIN USER
Code 1
can change its own PIN and
the PINs of: Code 3, Code 4, Code 5 and Code 7.
MAIN USER
Code 2
can change its own PIN and the PINs of: Code 6,
Code 7 and Code 8.
NC2TAST
or
ICON/KP
keypads can be connected to the Panel. The key
functions on the
NC2TAST
and
ICON/KP
keypads are identical, however, the
key icons differ. The following description refers to the
NC2TAST
keypad.
Access to programming
The control panel must be disarmed.
INSTALLER
Enter the INSTALLER PIN then press
.
PROGRAMMING FROM KEYPAD
5
Summary of Contents for Academy 4
Page 1: ......