![Bentel Security Academy 4 Programming Manual Download Page 20](http://html1.mh-extra.com/html/bentel-security/academy-4/academy-4_programming-manual_2735350020.webp)
Minutes: enter the minutes value of the established time of the test event----2 digits.
Delay
: enter the number of hours before the established time of the first
test event----4 digits maximum (refer o the example).
The
Delay
will start when the programming session closes and will be
counted from the
hour
value (e.g. programming session closed at
10:20
delay will start at
10:00
).
Example
Established time
17
:
30
every
Monday
Interval: 168
hours (7 days x 24 hours)
Minutes: 30
(established time
17
:
30
)
Programming session closed at
10:20 Monday
----from
10:00
to
17:00
=
9
hours therefore:
Delay: 9
The Test event will be generated at
17:30
----as the final sum includes the
programmed
Delay
of
9
hours and the programmed
Minutes
value of
30
.
However, if the first Test event is required at
17.30
on
Tuesday
or
Wednes-
day
, etc. the
9
hour
Delay
must be increased by
24
hours for each day.
Add.
Description
Data
159
Number of rings before answer
î
160
Enable / Disable Double call
î
Enable / Disable Callback
î
161
Teleservice telephone number (1-8)
Callback (9)
î
162
period in hh
î
163
minutes:mm
î
164
delay in hh
u
(before first test)
Codes (Addresses 165 through 256)
Each Code has the following: a PIN (4 to 6 digits), a Type, its assigned
Partitions, Type
A Arming Mode and Type B Arming Mode.
KEYS
CODE
TYPE
PARTITIONS
(ON=Assigned
OFF=Not Assigned)
TYPE A
ARMING
MODE
(ON=Arm
OFF=Disarm)
TYPE B
ARMING
MODE
(ON=Arm
OFF=Disarm)
Disabled
Partition 1
Partition 1
Partition 1
Main
User
Partition 2
Partition 2
Partition 2
User
Partition 3
Partition 3
Partition 3
Duress
Partition 4
Partition 4
Partition4
Patrol
-
-
20
Security System Control panel
Summary of Contents for Academy 4