10. Tank installation and air bleeding of system
2
5
Filter
NOTE: the filter must be
to the return line going into the AC Hot Water system, if it is not
ed Warranty will be VIOD.
All pipe work to run were
cable in 1/2” copper tube / plas c compliant to Australia Standards, all
pipe work
must be thermally insulated
to a minimum of 20mm thickness or RI rated for 4 meter runs
or 25mm if over 4 meter runs.
Potable
Water
In line
fi
lter supplied (warranty
void if not
Cold water in
Water is taken from a
fi
ng approximately 300mm above the
om of the tank and is heated and
returned into a
fi
ng 100mm lower.
Air Purging
Leave the return line disconnected and follow procedure.
Turn the main on slow and place
fi
nger over the outlet when the water
starts coming out. This will allow the water to then
fl
ow through the
pump and heat exchanger elimina ng any air in the system.
Connect and start
PLEASE NOTE: Do not ever run the system with no water in the heat exchanger of the Ac Hot water
system, this may result in part failure and warranty will be void.