8
.TROUBLESHOOTING
By means pressure readings:
1.Over charged with refrigerant.
1.Undercharged with refrigerant.
1.Outdoor fan blocked(cooling).
1.Air intake temperature of indoor unit too high.
2.Outdoor coil dirty (cooling).
3.Non-condensable gases in refrigerant circuit (e.g.air.).
2.Refrigerant leakage.
3.Air filter clogged/dirty (indoor unit).
4.Indoor fan locked (cooling).
5.Water temperature too cold.
1.Poor compression /no compression (compressor defective).
2.Non-condensable gases in refrigerant circult (e.g.oil)
3.Obstructed air-intake/discharge.
4.Short circuiting of hot air at condensing unit.
Too low
Too high
Normal
A little Low
A little High
Data
PRESSURE
PROBABLE CAUSE
Circuit
High side
Low side
High side
Low side
High side
Low side
High side
Low side
High side
Low side
BY MEANS OF DIAGNOSIS FLOW CHART
Generally,there are two kinds of troubles,i.e.starting failure and insufficlent cooling/heating.”Starting
Failure”is caused by electrical defect while”Insufficient Cooling/Heating” is caused by improper
application or defects in refrigerant circuit.
1. Diagnosis of Electric Circuit
2
1
Summary of Contents for BENDX ACHW 34
Page 1: ...AIR CONDITIONER WATER HEATER OPERATION MANUAL...
Page 7: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 34 BENDX ACHW 34 5...
Page 8: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 41 BENDX ACHW 51 BENDX ACHW 41 BENDX ACHW 51 6...
Page 9: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 65 BENDX ACHW 65 7...
Page 11: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 34 41 and 51 Model 34 41 and 51 9...
Page 12: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 65 Model 65 10...