3.Test Order
Atmospherics, Dynamic, and Safety test sets require separate units and can be processed in
parallel. EUT testing shall be performed serially within each set.
Set 1 (3 units)
Set 2 (3 units)
Set 3
Dynamics: Atmospherics:
Safety/EMC:
Package Drop
Temperature/Humidity, Operating
EFT
Package Vibration
Temperature/Humidity, Non-operating ESD
Shock Altitude,
Operating
EMI-Radiated
EMI-Conducted
EMI-Susceptibility
4. Noise Testing Standard
(1) Desk high is 75 cm
(2) Projector have to closed to the edge of
desk
(3) Noise meter high is 150 cm & title 30
degree
(4) The distance between noise meter and
projector is 100 cm
(5) Measured four surfaces and calculated
the noise value by log average.
(6) We have designed excel files to calculate
this value. (Avg_Noise.xls)
9