45
Factory OSD Menu
The service page needs to include that information: Model name, S/N, Vender, panel, scalar, F/W version, Monitor
on time, Backlight on time.
1. Trigger method: Press “Menu” key and Power on.
2. Press the Menu key will display the service page
3. Press menu key will close the service page.
4. Power off will quit the service mode
5. At the service mode, the key function is same as normal OSD define.
6. The timer can only reset at the service mode by “Timer Reset” (Timer Reset moves to SI factory Area). And
needs to have a warning message to double confirm the reset function.The timer should record up to 99999
hours and will be reset once launch.
7. Add BenQ logo on/off item, the default is “on”
8. Add the auto power on item, the default is “on”
9. Add the timer reset warning message, when select the timer reset item, then the warning message will display
and need to confirm it again and the default is “No”.
10. Panel type define need to have the panel version
11. F/W version need to define the dual or analog model
12. Add “Resolution Notice“ item, the default is “off”