21 Connector Camera
Fault Symptoms
Customer: GRT:
No or bad Camera
Camera Problems
Camera connector
Problems
Watch for oxidation and
damaged pads of the
Connector
caused by customer
SCRAP
- has to be send
separately to WSC
okay
Check the status of the
Connector visually
Use the resistor test
function of a
multimeter to check
connection between
spring contacts and
soldering contacts.
The value must be
~0
Ω
Exchange
Connector
Continue with
higher repair level
okay
not
okay
not
okay
- check for twisted or
bent contacts
- check for dry joints
Back to customer
without repair
Connector Camera
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding components!
Resolder new component afterwards.
E-commerce order number:
L36197-F5008-F341
Soldering temperature:
240 - 255°C
IRIS Diagnose Code:
9B100 Functionality / Integrated Camera / No Function
Company Confidential
2005©BenQ