OPERATIONS AND 

MAINTENANCE MANUAL 

 

For 

 

Benning Power Electronics 

 

 

SLIMLINE INVERTER 

24VDC @ 500VA 

48VDC @ 1000VA 

 

(028-0009-004 Rev B) 

 

 
 

SAVE THESE IMPORTANT 

SAFETY INSTRUCTIONS 

This manual contains important safety instruc- 

tions that should be followed during installation 

and maintenance of the Power System. 

 
 
 

 

 

11120 Grader Street 

Dallas, TX 75238 

214-553-1444, Fax 214-553-1355

 

Summary of Contents for Tebevert 1000

Page 1: ...24VDC 500VA 48VDC 1000VA 028 0009 004 Rev B SAVE THESE IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instruc tions that should be followed during installation and maintenance of...

Page 2: ......

Page 3: ...ating personnel 9 Downtime 9 Increases the reliability and lifespan of the system These manuals explain all the necessary information to unpack install and operate the BLI25000 Modular Inverter System...

Page 4: ......

Page 5: ...nation No 4219en R2 Issued August 8 2005 DTL Page 1 22pages Revision Checked Switch mode single phase sine wave Inverter Product line TEBEVERT Series TEBEVERT 500 and TEBEVERT 1000 19 3 5 with mechani...

Page 6: ...Switch mode single phase sine wave Inverter Product line TEBEVERT August 8 2005 DTL 2 21 No 4219en R2 Page left blank intentionally...

Page 7: ...6 2 General 7 3 Inverter 8 3 1 Design of the unit 9 3 2 Terminals and operating elements 10 3 3 Technical data 12 4 Assembly and commissioning 16 4 1 Device settings 16 4 2 Connecting the inverter 16...

Page 8: ...ation Danger to the operator Downtime Enhances the reliability and life span of the inverter Service Centre For reasons of operational safety and operational availability we recommend to regularly mai...

Page 9: ...ructions which must be followed to avoid danger to persons Indicates instructions which must be followed to avoid material damage All specifications in these operating instructions must be observed at...

Page 10: ...commercial AC bypass supply or the battery 4 Capacitors may be charged even when the unit is disconnected These must be correctly discharged by a qualified electrician before the connections or termi...

Page 11: ...wide range of applications in the field of telecommunications and other applications The output power of the inverter is either 500VA with 24VDC input models or 1000VA with 48VDC input models The inve...

Page 12: ...e Inverter Product line TEBEVERT August 8 2005 DTL 8 21 No 4219en R2 3 Inverter The DC input voltage of 24VDC or 48VDC depending on the model is converted inside the inverter to an AC voltage of 120VA...

Page 13: ...se sine wave Inverter Product line TEBEVERT August 8 2005 DTL 9 21 No 4219en R2 3 1 Dimensions of the unit Millimeter Inches 78 3 07 275 10 82 483 19 466 2 18 35 440 17 32 88 1 3 47 Fig 2 Dimension di...

Page 14: ...ront view of the inverter TEBEVERT 500 1 Unit switch ON OFF The inverter can be switched on and off with this push button switch 2 LED s for indicating the inverter status LED Color Meaning red Error...

Page 15: ...ximate load level Green Fig 4 Rear view of the inverter 1 X1 Copper bar threaded stud plus connection for the DC input of the inverter Arranged for x 5 8 two hole crimp lug 2 X3 inverter output recept...

Page 16: ...o 4219en R2 6 X5 potential free central fault signal X5 1 2 fault X5 1 3 no fault 7 X1 Copper bar threaded stud negative connection for the DC input of the inverter Arranged for x 5 8 two hole crimp l...

Page 17: ...A Input current with no load and rated voltage 1 0 A Tolerated residual ripple on the input voltage 5 rms AC bypass input AC voltage 120 VAC Frequency 60 Hz AC Output AC voltage 120 VAC Static voltage...

Page 18: ...real power 85 88 Weight 13 2 lbs 6 kg Tolerated temperature range without condensation 0 C 40 C without reduction 40 C 60 C Reduction 3 5 PN C Automatic High Temp Shut down 60 C Automatic re start aft...

Page 19: ...or Switching times 100 ms Switching thresholds of the input voltage monitoring 3 Setting parameter Default settings Lower switch off threshold U1 20 4 V Switch on threshold U2 24 5 V Switch on thresho...

Page 20: ...ting The inverter is designed to operate in a controlled environment Attention must be paid that the inverter is not exposed to aggressive airborne substances and that the passage of cooling air is no...

Page 21: ...e lugs 1 4 x 5 8 suitable for the cable cross section Recommended protection device 25A Fuse or Circuit Breaker Nominal range of tightening torque 4 5 6 Nm use 10mm socket wrench 3 Plug customer load...

Page 22: ...with the four included screws and rubber washers The wall mounting brackets can then be secured to the wall Check that the wall is firm and level When the inverter is mounted to a wall of concrete woo...

Page 23: ...is set to the operating mode inverter priority switch over takes place from the commercial AC bypass voltage to the inverter output 3 Switch on the loads The greater the connected load the more LED s...

Page 24: ...f the inverter output voltage falls below the programmed switch over voltage of the unit The switch over process can cause an interruption of the output power to the loads for a maximum duration of 10...

Page 25: ...Switch mode single phase sine wave Inverter Product line TEBEVERT August 8 2005 DTL 21 21 No 4219en R2 7 Appendix A Block diagram of the inverter...

Page 26: ...erter Product line TEBEVERT August 8 2005 DTL 22 21 No 4219en R2 Millimeter Inches 180 7 09 454 21 46 514 20 24 Figure 5 Wall inserts and or wall mounting screw placement and proper orientation of the...