6.6 Replacing the fuses
Technical data
5235 / 05/2022 en
BENNING MM 7-2
46
7
Technical data
Protection class
II (double or reinforced insulation)
Contamination level
2
Protection category
(DIN VDE 0470-1, IEC / EN 60529)
IP 40
1st digit: 4 = protection against access to
dangerous parts and protection against solid
impurities (diameter >1.0 mm)
2nd digit: 0 = no protection against water
Overvoltage category
• CAT III 1 000 V to earth
• CAT IV 600 V to earth
Housing dimensions
(length x width x height)
193 mm x 89 mm x 51 mm
Weight (batteries included)
0.420 kg
Battery life (alkaline batteries)
Approx. 150 h (without background lighting)
Silicone safety measuring lines (item no.: 10231315)
Standard
IEC / DIN EN 61010‑031 (VDE 0411‑031)
Overvoltage category
(only applies to the safety measuring lines,
additionally observe the limitations of the
device)
• With attachable protective cap:
– CAT III 1 000 V to earth
– CAT IV 600 V to earth
• Without attachable protective cap:
– CAT II 1 000 V to earth
Protection class
II (double or reinforced insulation)
Contamination level
2
Max. rated current
10 A
Length
1.0 m
Operation
Max. barometric altitude
2 000 m
Operating temperature
-20 … 55 °C (do not permanently expose the
device to sunlight; please observe the
limitations for current measurement
[
Max. relative air humidity
80 % RH (-20 … 31 °C),
linearly decreasing down to 50 % RH at 55 °C,
non-condensing
Operating conditions
To be used inside buildings in dry
environments
Storage
(remove the batteries from the device)
Ambient temperature
-20 … 60 °C (do not permanently expose the
device to sunlight)
Max. relative air humidity
80 % RH
Table 23:
Technical data