Push the new fuse into the centre of the holder.
-
Lock the battery compartment cover into place on the bottom part and tighten the screw.
-
Place the BENNING MM 12 into the rubber protection frame
O
.
See figure 13:
Fuse replacement
9.5 Calibration
Benning guarantees compliance with the technical and accuracy specifications stated in the
operating manual for the first 12 months after the delivery date.
To maintain the specified accuracy of the measurement results, the instrument must be
recalibrated at regular intervals by our factory service. We recommend a recalibration interval of
one year. Send the multimeter to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt
9.6 Spare parts
Fuse F 440 mA, 1000 V, 10 kA, D = 10 mm, L = 34.9 mm,
P.no. 10016655
Fuse F 11 A, 1000 V, 20 kA, D = 10.3 mm, L = 38.1 mm,
P.no. 10016656
10. How to use the protective rubber holster
- The safety measuring leads can be stored by coiling them round the protective rubber
holster
O
and clipping the probe into the holster
O
so that they are sufficiently protected
(see fig. 14).
-
You can clip one lead onto the protective rubber holster
O
in such a way that the measuring
probe projects. This allows you to bring the measuring probe and the BENNING MM 12 up
to the measuring point together.
-
The support at the back of the holster
O
can be used to prop the BENNING MM 12 up in
a diagonal position (to make reading easier) or to suspend it (see fig. 15).
-
The protective rubber holster
O
has an eyelet for suspending the unit in a convenient posi-
tion.
See figure 14:
Winding up the safety measuring leads
See figure 15:
Standing up the BENNING MM 12
11. Technical data of the measuring accessories
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth (
) and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protective class II (
), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Only use the measuring leads if in perfect and clean condition as well as according to this
manual, since the protection provided could otherwise be impaired.
-
Throw the measuring lead out if the insulation is damaged or if there is a break in the lead/
plug.
-
Do not touch the bare contact tips of the measuring lead. Only grab the area appropriate
for hands!
-
Insert the angled terminals in the testing or measuring device.