background image

Compact Multimeter 

with NCV

Instruction 

Manual

R5099

WA

RRANTY

WARRANTY

1 YEAR

1 AN

GAR

ANTIE

GARANTIE

WA

RRANTY

WARRANTY

GAR

ANTIE

GARANTIE

WA

RRANTY

WARRANTY

GAR

ANTIE

GARANTIE

White background

Transparent background

White

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Summary of Contents for R5099

Page 1: ...RANT Y W ARRANT Y 1 YEAR 1 AN GARANTIE G ARANTIE W ARRANT Y W ARRANT Y GARANTIE G ARANTIE W ARRANT Y W ARRANT Y GARANTIE G ARANTIE White background Transparent background White REED Instruments 1 877...

Page 2: ...nt Measurement 8 AC Current Measurement 8 Resistance Measurement 9 Capacitance Measurement 9 Frequency Measurement 9 Diode Measurement 10 Continuity Measurement 10 Non Contact AC Voltage Measurements...

Page 3: ...age that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Do not use the meter or test leads if they look damaged Do not use the...

Page 4: ...uble molded plastic housing 4 000 count backlit LCD display Low battery indicator and auto shut off CAT III 600V safety rating Included Test Leads Batteries Specifications AC DC Voltage Range AC 4 40...

Page 5: ...100 F Accuracy 50nF 4 rdg 30 dgt 500nF 3 rdg 15 dgt 5 50 100 F 4 rdg 10 dgt Resolution 0 01 0 1 1 10 100nF Frequency Range 9 999Hz to 60kHz Accuracy 0 1 rdg 5 dgt Resolution 0 001Hz to 0 001Mz General...

Page 6: ...2 F 10 to 50 C Dimensions 4 4 x 2 3 x 1 4 112 x 58 x 35mm Weight 6 3oz 180g Instrument Description SELECT HOLD Hz Compact Multimeter NCV R5099 FUSED MAX 400mA 600V CAT III 600V 1 2 4 5 3 6 7 8 9 AUTO...

Page 7: ...4 Note the measured value AC Voltage Measurement 1 Set the function dial to the position 2 Press the SELECT button to indicate AC on the LCD display 3 Measure the voltage by touching the test probe ti...

Page 8: ...re you wish to measure the current 4 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circuit 5 Apply power to the circuit 6...

Page 9: ...asurement 1 Set the function dial to the position 2 Press the SELECT button to select diode as indicated by on the LCD display 3 Measure the frequency by touching the test probe tips to the load in pa...

Page 10: ...ion dial to any position 2 Place the tip of the meter to the hot conductor or on the hot side of the electrical outlet 3 If AC voltage is present the detector light will illuminate NOTE The conductors...

Page 11: ...d resume normal operation Backlight To turn the backlight on or off press and hold the BACKLIGHT button for 2 seconds Battery Replacement When the low battery icon appears on the LCD the batteries mus...

Page 12: ...be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instruments shall no...

Page 13: ...ts com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unaut...

Page 14: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Reviews: