BENNING IT 130 

short instructions 

 

- 13 - 

 

1.11 Optional accessories 

Earthing set 

Earthing set consisting of 2 earth rods and 3 test cables 

2 x L = 20 m, 1 x L = 4.5 m 

item 

no.: 

044113 

 

Current clamp adapter 

BENNING CC 1

, 1 A - 400 A AC 

output: 1 mV per 1 A 

item 

no.: 

044037 

BENNING CC 3

, 0.2 A - 300 A AC/DC 

output: 1 mV/10 mV per 1 A  

item no.: 

044038 

 

Luminous intensity sensor 

BENNING luxmeter type B

  

item 

no.: 

044111 

For  the  planning  and  installation  of  interior  and  exterior 

lighting

 

 

"Commander" test plug

 

For shock-proof socket, switchable with "TEST" and "MEM" 

keys, with "PASS" / "FAIL" indication by means of green/red 

LED, PE contact electrode for detecting a phase voltage at 

the protective conductor connection (PE)

 

 

item 

no.:

 

044149

 

 

CEE measuring adapter

 

16 A, 5-pin, for measuring the voltage and phase sequence 

(rotary field) at 16 A CEE sockets

 

 

item 

no.: 

044148

 

 

40 m Measurement cable 

40  m  measurement  cable  with  winder  and  strap,  for  the 

measurement of protective conductors 

 

item 

no.: 

044039 

 

 

Barcode scanner

 

Barcode  scanner  with  PS/2  interface  for  identifying  the 

measuring point and renaming the storage location

 

 

item 

no.: 

009371

 

  

Summary of Contents for 044103

Page 1: ...Installation Tester BENNING IT 130 Short instructions GB Detailed instruction manual on enclosed CD Rom...

Page 2: ...o KG M nsterstra e 135 137 D 46397 Bocholt Phone 49 0 2871 93 0 Fax 49 0 2871 93 429 www benning de duspol benning de 05 2020 BENNING This document must not be reproduced or used in any other form wit...

Page 3: ...and fuses 11 1 10 Calibration and Service 12 1 11 Optional accessories 13 2 Measurements 14 2 1 Null balance compensation of the test cables 14 2 2 TRMS voltage V AC DC frequency and phase sequence r...

Page 4: ...inspection and repair Do not use the instrument in AC supply systems with voltages higher than 550 V AC Service repairs or adjustment of instruments and accessories is only allowed to be carried out b...

Page 5: ...isconnect all test cables accessories from the tester and from the installation and switch the tester off before opening the cover of the battery fuse compartment Dangerous voltages may be applied to...

Page 6: ...ntrast 8 ON OFF Switches the instrument power on or off The instrument automatically turns off 15 minutes after the last key was pressed 9 HELP CAL Help function with connection diagrams press for app...

Page 7: ...rying case item no 10008291 1 x Commander test probe switchable by means of TEST key item no 044155 1 x test cable with shock proof plug item no 10008295 1 x universal three wire test cable black blue...

Page 8: ...N Battery indication Battery capacity indication Low battery The storage battery charge condition is too low to ensure correct measuring results Recharge the storage batteries or replace the batteries...

Page 9: ...urrent clamp can be increased Measured signal is out of range clipped Results are impaired Simple error in the IT network Fuse F1 F2 or F3 is defective If one of the fuses F2 or F3 has blown the devic...

Page 10: ...T network RCD TESTING according to EN 61008 EN 61009 IEC 60364 4 41 BS 7671 AS NZS 3017 SET ISC FACTOR setting 0 20 3 00 SELECT COMMANDER ON OFF INITIAL SETTINGS CLAMP SETTINGS BENNING CC 1 044037 BEN...

Page 11: ...e batteries will be recharged automatically as soon as the charger is connected to the charging socket An integrated protective circuit controls the charging process Power supply socket polarity Note...

Page 12: ...rantees compliance with the technical and accuracy specifications stated in the operating manual for the first 12 months after the delivery date To maintain accuracy of the measuring results the devic...

Page 13: ...terior lighting Commander test plug For shock proof socket switchable with TEST and MEM keys with PASS FAIL indication by means of green red LED PE contact electrode for detecting a phase voltage at t...

Page 14: ...t the test cables Shorted test leads 3 Press the key 4 Press the key CAL HELP After performing test leads compensation first measured value and then 0 00 is displayed Successful compensation is displa...

Page 15: ...se adapter optional in a three phase system 3 The measuring result can be stored by means of the MEM key Uln Voltage between phase L and neutral conductors N Ulpe Voltage between phase L and protectiv...

Page 16: ...500 V 1000 V Minimum limiting value without 0 01 M 200 M 3 Connection diagrams Connection of 3 wire test lead and Commander probe tip 4 Press and hold the key until result is stabilized Double click...

Page 17: ...NUITY function 3 Connection diagrams Connection of the three wire test cable and of the optional measuring line BENNING TA 5 044039 Connection of 3 wire test lead and Commander probe tip 4 a R LOW low...

Page 18: ...actor for test current x I N 1 2 5 x I N Limiting value for contact voltage 25 V 50 V 3 Connection diagrams Connecting the Commander test plug optional TN 044149 and the 3 wire test lead 4 Press the k...

Page 19: ...CD Fuse type gL gG gG B C K D Nominal current of the fuse Tripping time of the fuse 3 Connection diagrams Connecting the Commander test plug 044149 and the 3 wire test lead 4 Press the key 5 The measu...

Page 20: ...tion of the optional Commander test plug 044149 and of the three wire test cable Voltage drop Connection of the optional Commander test plug 044149 and of the three wire test cable 4 Press the key 5 T...

Page 21: ...nce Maximum limiting value without 1 5 k 3 Connection diagrams Connection of the optional earthing set 044113 4 Press the key 5 The measuring result can be stored by means of the MEM key R Earth resis...

Page 22: ...unction I Note Please set the current clamp adapter used under SETTINGS 2 Connection diagrams Connection of the optional current clamp adapter BENNING CC 1 044037 BENNING CC 3 044038 4 Press the key 5...

Page 23: ...Set function 2 Set limit LUX Minimum illumination OFF 0 1 lux 20 klux 3 Connection diagrams Positioning of the luminous intensity sensor BENNING luxmeter type B 044111 4 Press the key 5 The measuring...

Page 24: ...t RISO ISFL Single fault leakage current only in IT networks Maximum limiting value without 3 0 mA 20 0 mA 3 Connection diagrams Connection of the three wire test cable 4 Press the key 5 The measuring...

Reviews: