background image

17

CLR

By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory.
If the code is valid, it will be stored in memory and OK will be displayed.
If the code is not valid, the Err message will be displayed.

RTR

The memory of the receiver is entirely erased. Confirmation for the operation is asked.

NUMBER OF CYCLES (

Nman

)

The number of cycles (open+close) completed by the system is displayed.
When the push-button <PG> is pressed once, the first 4 digits are displayed, if the push-button is pressed once more, 
the last 4 digits are displayed.
E.g. <PG> 0012 >>> <PG> 3456: 123.456 cycles were performed.

MAINTENANCE (

maci

)

This function allows to activate the indication of maintenance required after a certain number of operations, preset by 
the installer.
To activate and select the number of operations, proceed as follows:
Press the <PG> button, OFF is displayed, indicating that the function is disabled (default).   
Select one of the numbers shown (from OFF to 100) by using the <+> and <-> keys . The figures express the value of 
hundreds of cycles (e.g.:  the number 50 means 5000 operations).
Press OK to activate the function. The  PROG message is displayed.
The warning of maintenance required is indicated to the user through the flashing of the courtesy light LEDs during the 
opening and closing phases.

RESET (

RES

)

RESET of the control unit. WARNING: Returns the control unit to the default values.
When the <PG> push-button is pressed once, the RES wording begins to flash,  if the push-button<PG> is pressed 
once more, the control unit is reset.
Note: neither the transmitter codes nor the position and stroked of the gate leaf will be erased from the receiver. 

AUTOSET (

AUTO

)

The  self-calibration  of  the  triggering  thresholds  of  the  anti-crash  device  (amperometric  sensor),  as  well  as  the  stroke 
learning are performed. See paragraph SELF-LEARNING 

PASSWORD (

CODE

)

It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once 
the password is typed in, it is possible to act on the control unit by entering and exiting the programming mode for around 
10 minutes in order to allow adjustments and tests on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access 
to any other menu. If a protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one. 

BGUFSUZQJOHJOUIFDIBSBDUFSTBDPOmSNBUJPONFTTBHFi$0/'wBQQFBST

- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.

*GUIFDPEFDPSSFTQPOETUPUIFQSFWJPVTPOFBDPOmSNBUJPONFTTBHFi0,wBQQFBST

The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protection 
code must be typed in.

IMPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance operations. 
To remove the code from a protected control unit, enter the programming mode with the password and reset the 
code to the 0000 default value.
IF YOU LOOSE THE CODE, PLEASE CONTACT THE AUTHORISED SERVICE CENTER FOR THE TOTAL RESET OF 
THE CONTROL UNIT.

ATTENTION:

After any LOGIC change or control panel reset, it is necessary to perform a self-learning procedure 

(Menu Auto - See Stroke self learning)

Summary of Contents for CP.J4 ESA

Page 1: ...L8542920 04 2011 rev 0 CP J4 ESA UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI...

Page 2: ...00mA max 24Vac dc SCA Service Light R A D I O F1 T A COM P P STOP PHOT OPEN CLOSE BAR BAR SCA SCA BLINK BLINK 24V 24V N L F2 1AT 230V F2 2AT 115V MOT L1 AUX N1 L1 N1 0V OUT ENC M M ENC ANT ANT SHIELD...

Page 3: ...BLINK BLINK 24V 24V 8K2 4 2 3 SCA AUX1 0 BAR BAR SCA SCA BLINK BLINK 24V 24V SCA 24Vac 3W max 24Vac 1A max AUX1 1 II CH RADIO BAR BAR SCA SCA BLINK BLINK 24V 24V AUX1 2 SERVICE ZONE LIGHT Service Lig...

Page 4: ...ssential characteristics of the product unchanged the manufacturer reserves himself the right to bring any change of technical constructive or commercial character without undertaking himself to updat...

Page 5: ...push button Normally Open contact A timer clock can be connected for openings according to timeframes PHOT Photocell Input photocell is activated in the closing phase STOP STOP STOP button input N C...

Page 6: ...red values in the programming menus described below The parameters menu allows you to assign a numerical value to a function in the same way as a regulating trimmer The logic menu allows you to activa...

Page 7: ...ion of the opening operation 3 Area light The contact closes in the opening phase and remains closed for the entire TCA time It opens only with closed door 0 3 3 ATTENTION A wrong formulation of these...

Page 8: ...BWJOHT GVODUJPO JT BDUJWBUFE PS EFBDUJWBUFE On Enabled energy savings After around 10 sec of non operation the po wer supply is cut off from the accessory output and the system switches to stand by Of...

Page 9: ...paragraph SELF LEARNING PASSWORD CODE It allows to type in an access protection code to the programming of the control unit A four character alphanumeric code can be typed in by using the numbers fro...

Page 10: ...ring the door leaf stoke If the error occurs during self learning of the radio transmitters this means that the memory of the receiver is no longer able to receive other transmitters or the transmitte...