background image

13

CONTROL PANEL CP.J4 ESA 

WIRE DIAGRAM

Wire connections shown in Fig. 1 are described hereunder: 

Terminals

Function 

Description 

L/N

Power supply

Input, 230VAC 50/60 Hz (L-Phase/N-Neutral)

L1/N1

Primary
Transformer

Connector for the connection of the primary transformer
L1: Line 
N1: Neutral

0V/MOT/
AUX

Secondary
Transformer

Connector for the connection of the secondary transformer
0V: Input, 0V – MOT: 30 VAC - AUX: 18 VAC

M1

Motor

Fast connector for the connection of the motor equipped with Encoder

BAR/BAR

SAFETY 
EDGE

Input, safety edge. A 8.2 Kohm resistance is pre-installed on the terminals.
Safety edge of the resistive type, 8K2: connect the edge to the terminals by eliminat-
ing the pre-installed resistance, as shown in Figure 3.
Safety edge of the mechanical type: connect the edge in series to the resistance, as 
shown in Figure 3.
When the safety edge is activated, the door movement is stopped and reversed for 
around 3sec.

CLOSE

CLOSE 

Input,  CLOSE push-button (Normally Open contact).

OPEN

OPEN

Input,  OPEN push-button (Normally Open contact).
A timer/clock can be connected for openings according to timeframes.

PHOT

Photocell   

Input,  photocell is activated in the closing phase.

STOP 

STOP 

STOP button input (N.C. contact)

P.P. 

Step by step 

STEP BY STEP input ( N.O. contact)

+COM 

COMMON 

Common for all control inputs. 

SHIELD/ANT 

antenna

Connection antenna to the built-in receiver 
SHIELD: Screen / ANT: Signal 

+ 24V - 

24 Vac/dcs 

Accessories power supply 24Vac/1A max.
Warning: With the backup battery card CB.24V, the output (without mains) is 24Vdc 
(polarized). 
Check devices connection polarity. 

BLINK 

Flashing 

Connection to flashing light 24Vdc 15W max. 

SCA

AUX1

Normally open (N.O.), clean contact, which is configurable like SCA (open gate in-
dicator light) through parameter AUX1, second radio channel, courtesy or area light 
(see Parameter AUX 1).

TECHNICAL DATA

Contol unit power supply

24 Vdc

Power supply

230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version

Output 

1 motor 24Vdc

Motor maximum power 

220 W 

Accessories power supply 

24Vdc 1A max.

Protection level

IP40

Operating temp.

-20°C / +70°C

Radio receiver

built in 433,92 MHz confgurabile (rolling-code or progra rolling-code) 

Memory capacity

64 rolling-code transmitters

Summary of Contents for CP.J4 ESA

Page 1: ...L8542920 04 2011 rev 0 CP J4 ESA UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI PORTE SERRANDE ED AFFINI...

Page 2: ...00mA max 24Vac dc SCA Service Light R A D I O F1 T A COM P P STOP PHOT OPEN CLOSE BAR BAR SCA SCA BLINK BLINK 24V 24V N L F2 1AT 230V F2 2AT 115V MOT L1 AUX N1 L1 N1 0V OUT ENC M M ENC ANT ANT SHIELD...

Page 3: ...BLINK BLINK 24V 24V 8K2 4 2 3 SCA AUX1 0 BAR BAR SCA SCA BLINK BLINK 24V 24V SCA 24Vac 3W max 24Vac 1A max AUX1 1 II CH RADIO BAR BAR SCA SCA BLINK BLINK 24V 24V AUX1 2 SERVICE ZONE LIGHT Service Lig...

Page 4: ...ssential characteristics of the product unchanged the manufacturer reserves himself the right to bring any change of technical constructive or commercial character without undertaking himself to updat...

Page 5: ...push button Normally Open contact A timer clock can be connected for openings according to timeframes PHOT Photocell Input photocell is activated in the closing phase STOP STOP STOP button input N C...

Page 6: ...red values in the programming menus described below The parameters menu allows you to assign a numerical value to a function in the same way as a regulating trimmer The logic menu allows you to activa...

Page 7: ...ion of the opening operation 3 Area light The contact closes in the opening phase and remains closed for the entire TCA time It opens only with closed door 0 3 3 ATTENTION A wrong formulation of these...

Page 8: ...BWJOHT GVODUJPO JT BDUJWBUFE PS EFBDUJWBUFE On Enabled energy savings After around 10 sec of non operation the po wer supply is cut off from the accessory output and the system switches to stand by Of...

Page 9: ...paragraph SELF LEARNING PASSWORD CODE It allows to type in an access protection code to the programming of the control unit A four character alphanumeric code can be typed in by using the numbers fro...

Page 10: ...ring the door leaf stoke If the error occurs during self learning of the radio transmitters this means that the memory of the receiver is no longer able to receive other transmitters or the transmitte...

Reviews: