18
ERRoR mEssAGEs
The control unit checks the correct operation of the safety devices. In the event of faults the following messages can be
displayed:
ERR
Error, stroke self-learning or remote control code memorisationi.
ERR1
Error, PHOTOTEST PHOT O.
ERR2
Error, PHOTOTEST PHOT C.
ERR3
Error, Encoder.
EXAmPLE oF PRoGRAmmiNG
Let us suppose it is necessary to:
- set an automatic closing time (TCA) of 100s
- activate pre-blinking
Perform the operations described below step by step:
step
Press
display
Notes
1
PAR
First menu
2
TCA
First function of the first menu
3
040
Value currently set for the function selected
4
100
Set the desired value with the <+> and <-> keys
5
PRG
The value is programmed
TCA
When programming has been made, the display goes to the function just set
6
PAR
Press <+> and <-> simultaneously to go to the higher menu
7
Log
Second menu
8
TCA
First function of the second menu
9
Pre
Press <-> several times to select PRE logic
10
OFF
Value currently set for the function selected
11
ON
Set the desired value with the <+> and <-> keys
12
PRG
The value is programmed
Pre
When programming has been made, the display goes to the function just set
13
PAR
Press <+> and <-> simultaneously to go to the higher menu and quit programming or
wait 30s.
WAsTE disPosAL
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal and
the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a specialised
company.