BENE P2 Safety And Operating Instructions Manual Download Page 8

8

1. CONTROL UNIT FAILS TO OPERATE; GENERAL INSPECTION 

If the manually operated switch does not work and the 

controls do not beep, you need to check the following: 

 

•  Is the manual control switch in the right socket 

 

(see page 30)? 

•  Is the safety sensor plugged in? 

•  Is the power cable properly connected to the control unit? 

•  Is the power plug properly connected to the power socket? 

•  Does the socket provide power, and as it turned on? 

 

If the problem persists, contact your service centre. 

 

2. CONTROL UNIT DOES NOT OPERATE, 

AN ACOUSTIC SIGNAL IS GENERATED (BEEP) 

The control unit must first be reset. 

(see page 8, Reset control unit). 

 

•  The turn-on period for the controls has been exceeded, i.e., 

 

the mounting has been operated for longer than two minutes. 

•  The control unit will remain inactive for 18 minutes. 

 

Retry after this time has expired. 

•  Check the plug-in connections. 

•  In case of a power outage during operation the control unit 

 

must be reset (see page 8, Reset control unit). 

 

Contact your service centre if the control unit still fails 

to operate properly. 

3. LIFT MECHANISM DROPS DOWN 

The lift mechanism stops during operation and drops down 

a few mm in the opposite direction. The protection against 

uncontrolled movement has been activated. Possible reasons:

•  Object in the path of travel 

•  Monitor was moved 

•  Cable too short, safety sensor function 

 

 

 

The sensor is only activated one second after 

 

 

every operation. 

 

 

 

Wait for 5 seconds after the safety sensor has been  

 

 

activated and until movement of lift mechanism stops.

4. THE COLUMN IS STUCK IN EXTENDED POSITION 

Due to maintenance reasons the column remains in an exten-

ded position after 10,000 lifts. Please contact your service 

centre. 

 

5. THE MONITOR DOES NOT COME OUT COMPLETELY 

The table is clamped. Follow the following procedure. 

 

1.   

Loosen the attachment screws of the lift column.

2.   

Move the lift into top position.

3.   

Retighten the attachment screws.

TROUBLESHOOTING

Summary of Contents for P2

Page 1: ...T EN SAFETY AND OPERATING INSTRUCTIONS NOTE Please read all instructions carefully before operating the system Keep instruction manualfor further reference This document is alternative available on the official Bene homepage www bene com ...

Page 2: ...2 2 CONTENTS Contents 2 Product overview 3 Safety instructions 5 Troubleshooting 8 Capacitive manual switch 9 Cleaning instructions Certificates 10 Notes 11 EN ...

Page 3: ...VERVIEW Flatscreen holder Column sensor Motor cable Monitor support Compact control Capacitive manual switch Power cable Column safety sensors Connecting cable for the monitor Swivel unit Lifting mechanism Dual flap ...

Page 4: ...4 P2 with slab end P2 with sideboard PRODUCT OVERVIEW ...

Page 5: ...s are placed at a minimum distance of 25 mm to prevent them from being squeezed or sheared 7 Ensure that the safety distances are 25 mm for movable parts this also applies for organisational elements which are fitted above or underneath the furniture mounted to adjoining walls or building parts such as open windows 8 The protection against uncontrolled move ment does not prevent objects being trap...

Page 6: ...ty for damage resulting from improper use 17 Connection plug boards must be fixed properly for easy plugging and unplugging Plugs and connection plug boards must be located in such a way that no fluids come into contact with electrical equipment when the office furniture is used properly 18 The power cable must be secured in the strain relief of the leg frame Interconnecting cables may be run loos...

Page 7: ... frequency devices e g transmitters radiation equipment or similar devices Warning In the event of a fault it is possible that the table top moves a bit during every attempt whilst operating before the safety switch off kicks in Please take care to avoid the possible danger of crushin Warning During all reset procedures section 5 the collision protection is not active Please take care to avoid pos...

Page 8: ...ons In case of a power outage during operation the control unit must be reset see page 8 Reset control unit Contact your service centre if the control unit still fails to operate properly 3 LIFT MECHANISM DROPS DOWN The lift mechanism stops during operation and drops down a few mm in the opposite direction The protection against uncontrolled movement has been activated Possible reasons Object in t...

Page 9: ...ter the second tap leave your finger on the surface until the monitor moves in the desired direction The lift column automatically moves to the lower position Stop Tap once the lift column stops The down up function swit ches after each stop AUTOMATICALLY TURNING THE MONITOR ON AND OFF Connect the coupler provided in the assembly package to the control unit to automatically activate it The power s...

Page 10: ...nce is ruined Furniture polishes available off the shelf can be used for closed pore lacquered surfaces cherry beech and maple They fill the finest of scratches in the lacquer and cover them up relatively well An enhanced glossy appearance of the surface is difficult to prevent Never use polishes contain ing silicon caustic cleaning agents with ammonia additives DISPOSAL Instructions for the dispo...

Page 11: ...11 NOTES ...

Page 12: ...cs to product recycling Bene considers ecology to be a central element of its responsible and sustainable corporate strategy Bene sees the legal regulations as minimum requirements and strives for better and more sustainable environmental protection throughout the group The Bene principle in environmental policy is Avoidance Minimisation Recycling Disposal P2 Monitor Lift WP_MB120_SB_EN 032015 TE ...