OPEN
valves S3 and S4.
• Press the LOWER button until both ramps lower to the
floor.
•
CLOSE
valves S3 and S4.
•
OPEN
MAIN valve
Lift will not raise completely
Lower the lift until it reaches floor level.
•
CLOSE
MAIN valve.
•
OPEN
valves S3 and S4.
•
Press the RAISE button until lift approximately 24”
•
CLOSE
valves S3 and S4.
•
OPEN
MAIN valve
•
Press the LOWER button until the ramps are lowered
to the floor.
•
CLose the MAIN valve
•
Open S3 and S4 valves
•
Press the RAISE Button until the lift approximately 24”
above the floor.
•
•
Close the S3 and S4 Valves
•
Open the MAIN Valve
•
Press the LOWER button until the ramps are lowered
to the floor.
•
Repeat until the ramps cannot be lowered to the floor.
•
Close the MAIN valve.
•
Open S3 and S4 valves.
•
Press the LOWER button until the ramps are lowered
to the floor.
•
Close the S3 and S4 valves.
•
Open the main valve.
After Bleeding and Leveling the Baseplates have
moved out of position
•
Reposition the Baseplates to the correct posi-
tions before installing anchor bolts.
•
If a component has been replaced. Bleeding
and Leveling must be repeated with the hydraulic sys-
tem partially filled with fluid.
•
Call customer service immediately. The com
-
plexity of different situations requires Bendpak experts
to assist you in correctly bringing your lift back to
working condition.
OvER PRESSURE:
NOTE: Avoid pressing the raise button if the lift is in the
maximum raised position. The sound of the motor will
change in this situation. If the lift has been raised and
the “raise” button has continued to be pressed, press the
“lower” button for 1 second to relive system pressure.