This section describes how to install your SP-7XE/F. Perform the steps in the order listed.
⚠
WARNING
Use only the factory-supplied parts that came with your lift
. If you use
parts from a different source, you void your warranty and compromise the safety of
everyone who installs or uses the Lift. If you are missing parts, visit
(800) 253-2363
, extension 191.
Your Lift is supplied with installation instructions and concrete fasteners that meet the criteria set by
the current version of the American National Standard “Automotive Lifts – Safety Requirements for
Construction, Testing, and Validation”.
Lift buyers are responsible for regional, structural, and/or seismic anchoring requirements specified by
any other agencies or codes, such as the Uniform Building Code or International Building Code.
Safety Rules
When installing the Lift, your safety depends on proper training and thoughtful operation.
⚠
WARNING
Do not install this equipment unless you have automotive Lift installation training.
Always use proper tools, such as a Forklift or Shop Crane, to move heavy
components. Do not install this equipment without reading and understanding this
manual and the safety labels on the unit.
BendPak recommends referring to the ANSI/ALI ALIS Standard
Safety Requirements for Installation
and Service
for more information about safely installing, using, and servicing your Lift.
Only fully trained personnel should be involved in installing this equipment.
Pay attention at all
times.
Use appropriate tools and equipment. Stay clear of moving parts.
⚠
WARNING
You must wear protective equipment
at all times
during the installation: leather
gloves, steel-toed work boots, eye protection, back belts, and hearing protection.
Electrical Work
You will need to have a licensed, certified Electrician available at some point during the installation.
⚠
DANGER
All wiring
must
be performed by a licensed, certified Electrician in accordance with
all applicable local electrical codes.
The Electrician needs to:
34.
Connect the Power Unit to a 220 VAC power source
. This is generally done near the end
of the installation. Note that installing the Power Unit and connecting the Power Unit are separate
procedures; while anyone can install the Power Unit, the Electrician
must
connect the Power Unit
to Power. The Electrician must provide a Power Cord with an appropriate plug.
35.
Install a Power Disconnect Switch
. A Power Disconnect Switch gives you a way to shut
down the Lift in the event of an electrical circuit fault or emergency situation. Refer to
Summary of Contents for SP-7XE
Page 56: ...SP 7XE F Full Rise Scissor Lift 56 P N 5900010 Rev B June 2022 Labels ...
Page 57: ...SP 7XE F Full Rise Scissor Lift 57 P N 5900010 Rev B June 2022 ...
Page 58: ...SP 7XE F Full Rise Scissor Lift 58 P N 5900010 Rev B June 2022 Parts Diagrams ...
Page 59: ...SP 7XE F Full Rise Scissor Lift 59 P N 5900010 Rev B June 2022 ...
Page 60: ...SP 7XE F Full Rise Scissor Lift 60 P N 5900010 Rev B June 2022 ...
Page 61: ...SP 7XE F Full Rise Scissor Lift 61 P N 5900010 Rev B June 2022 ...
Page 62: ...SP 7XE F Full Rise Scissor Lift 62 P N 5900010 Rev B June 2022 ...
Page 63: ...SP 7XE F Full Rise Scissor Lift 63 P N 5900010 Rev B June 2022 ...
Page 64: ...SP 7XE F Full Rise Scissor Lift 64 P N 5900010 Rev B June 2022 ...
Page 65: ...SP 7XE F Full Rise Scissor Lift 65 P N 5900010 Rev B June 2022 ...
Page 66: ...SP 7XE F Full Rise Scissor Lift 66 P N 5900010 Rev B June 2022 Maintenance Log ...