17
4. Tighten each Nut until there is at least one inch of
threads protruding through the top of the nut. The Cables
will remain loose until start up and final Cable adjust
-
ments are made. (See Fig. 8.4)
5. After routing the Cables double-check to make sure
all are properly positioned and remain within the grooves
of ALL Sheaves. (See Fig. 8.5 - 8.6)
STEP 9
( Power Unit Installation )
1. . Mount the Power Unit, the Flex Tube Mount-
ing Bracket, the Vibration Dampener and the Air Valve
Mounting Bracket to the Power Unit Mounting Bracket us-
ing the M8 hex bolts and nylock nuts then fill the reservoir
with 12 quarts of 10-WT hydraulic oil or Dexron III auto-
matic transmission fluid. . (See Fig. 9.1)
DANGER!
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITH OUT
FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR PANEL
AND CANNOT BE RE-ENERGIZED UNTIL ALL
MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
DANGER !
ALL WIRING MUST BE PERFORMED
BY A LICENSED ELECTRICIAN.
Fig 9.1
Fig 8.4
Fig 8.5
Fig 8.6
Fig 8.3