background image

MDS-6 Series Product Decal Positioning

R

S

Power_Unit_Caution_Label.pdf:

Trim: 2.5”W x 6.5”H
Material: 4 Mil. White Adhesive Vinyl
Ink: U.V. protected CMYK 4/C Process
Finish: Matte Overlaminate (No gloss)
Print Process: Offset Lithography - 200 line-

screen or 300 p.p.i. for digital
Lamination: Clear laminate non-glare medium 

matte over-laminate (No gloss) for abrasion, 

chemical and ultra violet protection. 

1. Motor not protected - external 

overheat protection in accordance 

with CE code, Part 1, shall be 

provided.

2. Minimum circuit ampacity of 

conductor is 30A.

1. Moteur non protégé - une 

protection externe contre la 

surchauffe conforme au code CE, 

Partie 1, doit être fournie.

2. L’ampacité minimale du circuit du 

conducteur est de 30A.

1. Motor no está protegido - se 

proveerá protección contra 

sobrecalentamiento externo de 

conformidad con el código CE,  

Sección 1.

2. Ampacidad mínimo del conductor 

del circuito es 30A.

If connected to a circuit protected by 

fuses use time-delay fuse Marked D

Si está conectado a un circuito 

protegido por fusibles, utilice 

fusibles de acción retardada, tipo D

Si connecté à un circuit protégé 

par fusibles utilisez fusible 

temporisé Marqué D

CAUTION

ATTENTION

PRECAUCIÓN

REV. 1119

P

Q

ST_Motor_Tag.pdf:

Trim: 4”W x 2”H
Material: 2 Mil. White Adhesive Vinyl
Ink: U.V. protected CMYK 4/C Process
Finish: Matte Overlaminate (No gloss)
Print Process: Offset Lithography - 200 line-screen or 300 p.p.i. for digital
Lamination: Clear laminate non-glare medium matte over-laminate (No gloss) for abrasion, 

chemical and ultra violet protection. 

 HP: 

 VOLT: 

 VOLT: 

 Hz: 

 FLA: 

 FLA: 

 KVA: 

 PH: 

 FRAME: 

 SF: 

 EFF%:  

 TANK: 

 

 TYPE: 

 DES: 

 DATE: 

 CODE: 

 I.D. NO: 

 NOT THERMALLY PROTECTED

 RPM: 

 MAX. AMB. ºC: 

 INS CLASS: 

MADE IN CHINA

WARNING: 

GROUNDINGS - Failure to connect the 

motor frame to equipment grounding conductor by 

using the grounding cord, green screw, or green

wire provided, may result in serious electric shock.

TENV

 SKU NO:  

www.rangerproducts.com

ENGINEERED BY

RANGER PRODUCTS USA

Ranger Products is a registered trademark of BendPak Inc.

BENDPAK

RANGER 

 PRV: 

 DUTY/DEVOIR: 

 

O

Operating_Explosion_Warning_Label.pdf:

Trim: 6”W x 4”H
Material: 4 Mil. White Adhesive Vinyl
Ink: U.V. protected CMYK 4/C Process
Finish: Matte Overlaminate (No gloss)
Print Process: Offset Lithography - 200 line-

screen or 300 p.p.i. for digital
Lamination: Clear laminate non-glare medium 

matte over-laminate (No gloss) for abrasion, 

chemical and ultra violet protection. 

ONLY FOR LP MODELS

USE APPROPRIATE TAG AS ASSIGNED

N

Pressure_Warning_Label-Power_Unit.pdf:

Trim: 4”W x 4.25”H
Material: 4 Mil. White Adhesive Vinyl
Ink: U.V. protected CMYK 4/C Process
Finish: Matte Overlaminate (No gloss)
Print Process: Offset Lithography - 200 line-

screen or 300 p.p.i. for digital
Lamination: Clear laminate non-glare medium 

matte over-laminate (No gloss) for abrasion, 

chemical and ultra violet protection. 

This power unit contains a hydraulic pump that is capable 

of developing pressure in excess of 5,000 psi (345 BAR). 

A pressure relief valve is used to set the pressure at 

the desired level. Tampering with, adjusting, modifying, or  

removing the relief valve is extremely dangerous and is not recommended. Only a trained hydraulics  

technician, using a calibrated hydraulic pressure gauge to assure the proper pressure setting is 

achieved, should make adjustments to the relief valve.

WARNING: Changes to the output pressure may render the power unit incompatible with pressure 

limitations of other components in the hydraulic circuit. This may cause catastrophic failure of 

those components, and could result in property damage, serious personal injury, or death.

Esta central hidráulica contiene una bomba capaz de  

desarrollar una presión en exceso de 5,000 psi (345 BAR). 

La presión está establecida por la válvula de descarga al 

nivel de presión deseada. Es extremamente peligroso y 

no está recomendado, descomponerla, modificarla, ajustarla o removerla. Solo un técnico cualificado,  

utilizando un manómetro hidráulico calibrado para asegurar que la propia presión es alcanzada,  

podrá hacer modificaciones a la válvula de descarga.

ADVERTENCIA: Cambios a la salida de presión, podrían hacer la central hidráulica incompatible 

con las limitaciones de presi6n de otros componentes en el circuito hidráulico. Esos componentes 

podrían funcionar mal causando una catástrofe y podría resultar en daño a la propiedad, serio daño 

personal o muerte.

Dieses Hydraulikaggregat beinhaltet eine Pumpe,welche 

einen Betriebsdruck bis zu 345 bar aufbauen kann.  

Ein integriertes Druckbegrenzungsventil begrenzt 

diesen Betriebsdruck. Missbrauch, verandem der 

Druckeinstellung,technische Veranderungen oder entfemen des Ventils, sind extrem gefiihrlichund daher 

nicht zu empfehlen. Nur qualifiziertes Personal mit Hydraulikerfahrung, solite unter Verwendung eines  

kalibrierten Manometers den Druck dieses Sicherheitsventils einstellen.

WARNUNG: Elne Veranderung des Betriebsdruckes am Aggregat, kann zu Problemen bei anderen 

angeschosenen Komponenten fuhren, welche nur uber einen gerlngeren zUlassigen Betrlebsdruck 

verfugen. Dies kann zur vollstandigen Zerstorung dieser Gerate fiihren und zusitzlich zu sehweren 

Verletzungen oder sogar zu Lebensgefahr beim Bedienpersonal fuhren.

Cet équipement utilise une pompe hydraulique capable 

de fournir une pression de 345 bar. Une soupape de sureté 

est utilisée pour régler la pression à la valeur souhaitée.  

Altérations, réglages, modifications ou suppression de 

cette soupape de sureté peuvent se révéler très dangereux et ne sont absolument pas recommandes. 

Uniquement un hydraulicien qualifie, utilisant un manomètre pour permettre I’ affichage précis de la  

pression, pourra assurer les réglages de la soupape de sureté.

AVERTISSEMENT: Tout changement de la valeur de la pression de sortie peut rendre incompatible 

I’ utilisation de cet équipement avec les autres composants du circuit hydraulique. Ceux-ci peuvent 

être endommages de manière définitive et peuvent causer des dégâts matériels, ainsi que des  

risques de blessures séreuses ou la mort.

  Warning

 aDVErTEnCia

  Warning

 aVErTiSSEMEnT

WARNING

ATTENTION

Always allow a minimum 2-second delay 

between motor starts. Failure to comply 

may cause switch and/or motor burnout. 

This could cause serious damage to the 

equipment and/or personal property. 

Prévoyez toujours un délai minimum de 2 

secondes entre les démarrages du moteur. 

Le non-respect de cette consigne peut 

entraîner l’épuisement des commutateurs et/

ou du moteur. Cela pourrait causer de graves 

dommages à l’équipement et/ou aux biens 

personnels.

All wiring must be performed by a certified 

electrician only. It is the responsibility 

of the electrician to ensure that all field 

wiring systems comply with both NEC 

recommendations and all additional 

electrical codes.

Tout le câblage doit être effectué par un 

électricien certifié. Il incombe à l’électricien 

de s’assurer que tous les systèmes de câblage 

sur site sont conformes aux recommandations 

NEC et à tous les codes électriques 

supplémentaires.

This equipment has internal arcing or 

sparking parts which should not be 

exposed to flammable vapors.

THIS EQUIPMENT SHOULD BE 

LOCATED AT LEAST 460 MM

(18 INCHES) ABOVE THE FLOOR.

Cet équipement comporte des pièces internes 

produisant des arcs électriques ou des 

étincelles qui ne doivent pas être exposées à 

des vapeurs inflammables.

CET ÉQUIPEMENT DOIT ÊTRE SITUÉ 

AU MOINS 460 MM (18 POUCES) AU-

DESSUS DU SOL.

RISK OF EXPLOSION

RISQUE D’EXPLOSION

PN 5906015

 

PN 5906015 

MET LISTED

Conforms to

ANSI/UL 201

SAFETY STANDARD FOR 

GARAGE EQUIPMENT

CERTIFIED AUTOMOTIVE LIFT

ALI CERTIFIED

To the provisions of

ANSI/ALI ALCTV-2017

Certification Label Serial Number

Automotive Lift Institute, Inc.  |   Cortland, NY 13045

SAFETY REQUIREMENTS FOR 

CONSTRUCTION, TESTING 

AND VALIDATION

MET Laboratories, Inc.

BALTIMORE, MD 21230

NR

TL LISTED

®

MET

US

A L X X S A M P L E X X N

ALI Gold Label

SAMPLE

Slippery_When_Wet_Label-5905138.pdf: 

Size: 4.5”W x 2.5”H
Material: White Vinyl Pressure Sensitive Adhesive
Thickness: 4 Mil
Ink: U.V. protected CMYK 2/C Process
Finish: Matte Overlaminate (No gloss)
Print Process: Offset Lithography - 200 line-screen 

or 300 p.p.i. for digital
Lamination: Clear laminate non-glare medium 

matte over-laminate (No gloss) for abrasion, 

chemical and ultra violet protection. 
PN 5905138

 

SLIPPERY WHEN WET OR ICY

Use caution when driving onto wet or icy drive-up ramps

and platforms. 

DO NOT

 

walk on lift surfaces that are wet or icy.

GLISSANT LORSQU’IL EST MOUILLÉ OU GLACÉ

Soyez prudent lorsque vous conduisez sur des rampes 

d’accès mouillées ou verglacées et les plateformes. 

NE PAS

 

marcher sur des surfaces de levage humides ou glacées.

WARNING

!

AVERTISSMENT

!

PN 5905138

Summary of Contents for 5175151

Page 1: ...tatives Office Tel 1 805 933 9970 Toll Free US Canada 1 800 253 2363 Fax 1 805 933 9160 sales bendpak com International Sales Service Office Tel 1 805 933 9970 Exports Dept 1 805 933 9970 EXT 192 Ext Toll Free US Canada 1 800 253 2363 Fax 1 805 933 9160 bpkexports bendpak com Service Manual SERVICE PARTS DIAGRAMS This guide is a troubleshooting reference used for maintaining and servicing your Ben...

Page 2: ...LE NAME DATE CHECKED DRAWN A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED NOTE UNLESS OTHERWISE SPECIFIED TM 5260676 MDS 6EXTF PRODUCTION LIFT VER D 03 09 2022 DO NOT SCALE DRAWING 1 25 SCALE THIRD AN...

Page 3: ...LL RISE 5 243in 133 2mm FULLY LOWERED 34 908in 886 7mm TOP LOCK 23 907in 607 2mm LOWEST LOCK SHEET 2 OF 3 REV DWG NO A SIZE TITLE A 1645 LEMONWOOD DR SANTA PAULA CA 93060 5260676 MDS 6EXTF PRODUCTION LIFT VER D 1 20 SCALE ...

Page 4: ...986 0 MIN 2136mm 0 MAX 78 740in 2000 0mm 14 094in 358 0mm 54 075in 1373 5mm 40 217in 1021 5mm 13 858in 352 0mm 132 283 MIN 138 189in MAX 3360 0 MIN 3510mm 0 MAX SHEET 3 OF 3 REV DWG NO A SIZE TITLE A 1645 LEMONWOOD DR SANTA PAULA CA 93060 5260676 MDS 6EXTF PRODUCTION LIFT VER D 1 20 SCALE ...

Page 5: ... LARGE 1 C 23 5530374 SSS M8 x 1 25 x 16 EXTENDED NL 2 24 5550310 FTG TEE 04JIC 04JIC 04JIC 1 25 5550001 FTG NPL 04 COMP x 02 NPT 2 26 5550087 FTG ELB 04 COMP x 02 NPT 1 27 5756033 MDS 6 CYLINDER SEPARATOR 1 C 28 5570060 MDS 6 SERIES HYDRAULIC HOSE ASSY Ø6 35 x 254mm SB 2 D 29 5545001 WASHER 25mm x 37mm 2 30 5530031 HHB M6 x 1 0 x 12mm 6 WHERE USED MDS 6EXT MDS 6EXTF REVISION REV DESCRIPTION DATE ...

Page 6: ...8 19 21 20 27 22 28 24 25 29 5 1 23 DETAIL A SCALE 1 5 26 15 13 12 11 10 16 14 DETAIL B SCALE 1 2 8 30 SHEET 2 OF 2 REV DWG NO A SIZE TITLE A 1645 LEMONWOOD DR SANTA PAULA CA 93060 5216122 MDS 6EX RAMP ASSEMBLY 1 16 SCALE ...

Page 7: ...SION REV DESCRIPTION DATE EDITED BY ECO G REMOVED 5590175 UPDATED BOM REVISION 03 27 2020 TM 01152 H ADDED 5250062 1 11 04 2020 TM 01212 J REPLACED 5570079 WITH 5570081 04 27 2022 TM 01403 WHERE USED MDS 6EXTF SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN J 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPE...

Page 8: ...ESCRIPTION DATE EDITED BY ECO D ADDED 3 5550395 AND 5550089 09 19 2019 TM 01128 E ADDED 5580012 03 12 2020 CA 01137 F REMOVED 5550087 AND 5550486 03 27 2020 TM 01152 WHERE USED MDS 6EXTF MDS 6LPF SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN F 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK...

Page 9: ... SERIES DLR 6 SERIES MDS 6 SERIES P9000LT SERIES SP 7XE SERIES SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED NOTE UNLESS OTHERWISE SPECIFI...

Page 10: ...DED 5905138 01 18 2021 CA 01212 F ADDED 5905775 08 18 2021 TM 01327 G REPLACED LABELS WITH COLORS GRAPHICS NOTE UPDATED BOM REVISION 09 21 2021 CA 01339 WHERE USED P9000LT P000LTF MDS 6EXT MDS 6EXTF MDS 6LP MDS 6LPF SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN G 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE...

Page 11: ...G NPL 02 NPT x 04 F NPT 1 7 5550087 FTG ELB 04 COMP x 02 NPT 1 WHERE USED XR 12AE SP 7XE SERIES P9000LT SERIES MDS 6 SERIES NEXT ASSEMBLY 5215780 5215781 SHEET 1 OF 1 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN C 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOL...

Page 12: ...LE NAME DATE CHECKED DRAWN D 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED TM 5570060 MDS 6 SERIES HYDRAULIC HOSE ASSY Ø6 35 x 254mm SB 12 15 2014 DO NOT SCALE DRAWING 1 2 SCALE THIRD ANGLE PROJECTION ...

Page 13: ...OD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED TM 5570081 HYDRAULIC HOSE ASSEMBLY Ø6 35 x 3352mm DB 07 28 2016 DO NOT SCALE DRAWING 1 2 SCALE THIRD ANGLE PROJECTION DB 3 16 2017 DIMENSIONS ARE IN MM TOLERANCES 0 1 ...

Page 14: ...PSI OR 393 BAR WORKING PRESSURE MINIMUM 17100PSI OR 1179 BAR MINIMUM BURST PRESSURE MINIMUM 3 80mm MIN BEND RADIUS COLOR BLACK ADDITIONAL CONTACT INFORMATION Xin Yurong Shandong Ningjin High Energy Hose Co Ltd Tel 86 534 5421821 No 7 Taishan Rd Industrial Park Ningjin County Shandong China Approved Vendor Vendor Part Contact AUTHORIZED COMPONENT PROVIDER 1 Ningjin Hydraulic Hose Co 5570129 86 534 ...

Page 15: ... DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED TS 5570911 MDS 6 SERIES HYDRAULIC HOSE ASSY Ø6 35 x 458mm DS 12 09 2016 DO NOT SCALE DRAWING 1 2 SCALE THIRD ANGLE PROJECTION DB 03 16 2017 DIMENSIONS ARE IN MM TOLERANC...

Page 16: ...M CA 00806 01137 J REPLACED BUSHINGS WITH CORRECT MATERIAL 08 18 2021 TM 01327 WHERE USED MDS 6 SERIES SHEET 1 OF 2 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN J 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS ...

Page 17: ... 2017 03 13 2020 TM CA 00806 01137 NEXT ASSEMBLY 5215121 5216122 SHEET 1 OF 2 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN E 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED TM 5600747 MDS 6 CYLINDER G...

Page 18: ...TION DATE EDITED BY ECO E UPDATED BOM REVISION 03 08 2019 TM 01055 F F 001 UPDATED BOM REVISION ADDED 20 GLOSS PAINT NOTE 09 17 2019 03 12 2020 TM CA 01128 01137 G REPLACED 5565358 WITH 5565029 08 18 2021 TM 01327 WHERE USED MDS 6 SERIES SHEET 1 OF 2 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN G 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN TH...

Page 19: ...171 SHEET 1 OF 2 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED TM 5601533 MDS 6EX RAMP WELDMENT 06 29 2020 DO NOT SCALE DRAWING 1 14 SCALE THIRD ANGLE ...

Page 20: ... FROM 5601534 03 09 2022 TM 01403 SHEET 1 OF 3 REV DWG NO A SIZE TITLE NAME DATE CHECKED DRAWN A 1645 LEMONWOOD DR SANTA PAULA CA 93060 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC IS PROHIBITED TM 5601797 MDS 6EX BASE WELDMENT 03 09 2022 DO NOT SCALE D...

Page 21: ...escription Print Settings Unless otherwise specified use these settings for printing BendPak manuals Size A4 210 to 297 mm 8 5 by 11 inches 216 to 279 mm or between Color Black and White Binding Saddle Stitched Paper 100 to 120 gsm 27 to 32 pound uncoated 2 Vendor Information Or for Reference ApprovedVendor Vendor Part Contact Preferred Vendor 1 OR BENDPAK ENGINEERING APPROVED EQUIVALENT ...

Page 22: ...l Pressure Sensitive Adhesive Thickness 4 Mil Ink U V protected CMYK 2 C Process Finish Matte Overlaminate No gloss Print Process Offset Lithography 200 line screen or 300 p p i for digital Lamination Clear laminate non glare medium matte over laminate No gloss for abrasion chemical and ultra violet protection 6000 LBS 2722 KGPN 5905308 TOTAL LIFT CAPACITY CAPACITÉ DE LEVAGE TOTALE Maximum load on...

Page 23: ...RLOAD LIFT Check for 1 minimum clearance between car and lift before raising NE JAMAIS SURCHARGER L ASCENSEUR Vérifiez le dégagement minimum de 1 entre la cabine et l ascenseur avant de soulever DRIVE CAR COMPLETELY OVER LIFT CONDUISEZ LA VOITURE COMPLÈTEMENT SUR L ASCENSEUR ALWAYS ensure that the safety is in LOCKED position before any attempt is made to work on or near the vehicle TOUJOURS s ass...

Page 24: ...idráulico Esos componentes podrían funcionar mal causando una catástrofe y podría resultar en daño a la propiedad serio daño personal o muerte DiesesHydraulikaggregatbeinhalteteinePumpe welche einen Betriebsdruck bis zu 345 bar aufbauen kann Ein integriertes Druckbegrenzungsventil begrenzt diesen Betriebsdruck Missbrauch verandem der Druckeinstellung technischeVeranderungenoderentfemendesVentils s...

Page 25: ...MDS 6 Series Product Decal Positioning A A B B L I F C C E F G G H H D D D D K P N M Q R O A B D F G H Place labels on all 4 sides of lifts inside and outside J S ...