CHANNEL SETTINGS
At the starting point for Channel 0, the LCD will display
PRG Ch 00.
At
this point, a channel number can now be pressed to allow access to the
frequency, Code Guard values, and alphanumeric label for that channel.
NOTE:
A valid receive frequency must be programmed into each
channel intended for use.
If a 0 value or an invalid
frequency is programmed, the LCD will give a false reading
in the operation mode, and may result in radio malfunction
If a malfunction occurs, reset the radio by turning it off and
1
then back on
RECEIVE FREQUENCY
1 .
2
q
3
Press 1 and the LCD will display
PRG
CH
01. This is the starting point for
entering channel 1 values
To move to the next channel, such as
from 1 to 2, press the
[PRI]
key.
Press the
[FCN]
key and the upper
part of the LCD will display
PRG RX.
This is the receive frequency for
channel 1 (in MHz).
If the displayed frequency is correct,
press the
[FCN]
key to advance to the
next value.
If a new frequency is desired, press
the
[CLR]
key followed by the digits of
the desired frequency. Then press
the
[ENT]
key to store this frequency
and automatically advance to the next
value.
RECEIVE CODE GUARD
After the receive frequency is set, the
upper part of the LCD will display
PRG RX
CG. This is the Code Guard value for
Channel 1 receive.
NOTE:
0.0
indicates carrier squelch
operation (no Code Guard).