background image

6 CC613_D00381_04_M_XXEN/11.2020

General instructions 

1.5 

Inspection, transport and storage

Check the shipping and device packaging for transport damage and scope of delivery. The following must be 
observed when storing the devices:

1.6 

Warranty and liability

Warranty and liability claims in the event of injury to persons or damage to property are excluded in case of:

Improper use of the device.

•  Incorrect mounting, commissioning, operation and maintenance of the device.
•  Failure to observe the instructions in this operating manual regarding transport, commissioning, 

operation and maintenance of the device.

•  Unauthorised changes to the device made by parties other than the manufacturer.
•  Non-observance of technical data. 
•  Repairs carried out incorrectly.
•  Use of accessories and spare parts not recommended by Bender.
•  Catastrophes caused by external influences and force majeure.
•  Mounting and installation with device combinations not recommended by the manufacturer.

This operating manual and the enclosed safety instructions must be observed by all persons working with the 
device. Furthermore, the rules and regulations that apply for accident prevention at the place of use must be 
observed.

1.7 

Disposal of Bender devices

Abide by the national regulations and laws governing the disposal of this device. 

For more information on the disposal of Bender devices, refer to 

www.bender.de -> Service & support.

1.8 

Safety

If the device is used outside the Federal Republic of Germany, the applicable local standards and regulations 
must be complied with. In Europe, the European standard EN 50110 applies.

 

I

D

anger

Risk of electrocution due to electric shock! 

Touching live parts of the system carries the risk of: 

•  A fatal electric shock
•  Damage to the electrical installation
•  Destruction of the device

Before installing and connecting the device, make sure that the installation has been de-energised. The rules 
for working on electrical systems must be observed.

Summary of Contents for CC613

Page 1: ...Manual EN CC613_D00381_04_M_XXEN 11 2020 CC613 charge controller Charge controller for use in electric vehicle charging stations wallboxes or street light charging points...

Page 2: ...cents 30 sec remaining time 6 3 cents min Mobile phone higher depending on mobile phone tariff Repair service Repair calibration and replacement service Londorfer Strasse 65 35305 Gr nberg Germany Tel...

Page 3: ...1 General functions 8 2 4 2 Load current and cooling control temperature monitoring 9 3 Dimensions and mounting 10 3 1 Dimensions 10 3 2 Mounting 10 4 Connection 11 4 1 Connection conditions 11 4 2 Co...

Page 4: ...5 Configuration and testing 20 5 1 Configuration 20 5 1 1 Local configuration of parameters 20 5 1 2 Remote configuration of parameters 21 5 1 3 Factory settings 22 5 1 4 Testing and system boot proc...

Page 5: ...low level risk that can result in minor or moderate injury or damage to property if not avoided i i Information can help to optimise the use of the product 1 2 1 Signs and symbols Disposal Temperatur...

Page 6: ...e Mounting and installation with device combinations not recommended by the manufacturer This operating manual and the enclosed safety instructions must be observed by all persons working with the dev...

Page 7: ...tions with two charging points 1 charge controller as data gateway with 4G modem and 1 charge controller as slave without 4G modem Dynamic load management to optimally distribute the available power a...

Page 8: ...he scope of delivery The SIM card slot available on data gateways with a 4G modem only is located on the charge con troller front panel The SIM card can have a PIN number which can be configured via t...

Page 9: ...rrent transfor mer plug 2 4 2 Load current and cooling control temperature monitoring The charge controller is equipped with a temperature sensor which allows the temperature in the environ ment of th...

Page 10: ...Note Dimensions in mm acc to ISO 2768 m Dimensions incl antenna socket 3 2 Mounting i i DIN rail mounting Lateral distance to other equipment 6 mm self heating In horizontal mounting position the max...

Page 11: ...power supply IEC 61851 series of standards Lay cables only inside the wallbox charging station and not in parallel with power cables Connect external Modbus to terminal block I using a shielded cable...

Page 12: ...B Mod PP PE 12V A Mod D B A C K J I H E F G L H WA 24 WB 23 B In B 14 HS2 In A 13 HS1 I A2 B2 GND2 AC DC 0V 12V n p H V m o 1 2 CT 0V PE B Modbus CP 12V PE A Mod PP WA Relais 23 WB Relais 24 230V only...

Page 13: ...an energy management system and is not intended for connecting a meter Terminal assignment B 0V Input 0V I GND2 External Modbus GND shield connected on one side 12V Supply voltage 12V B2 External Modb...

Page 14: ...0300 9743205000 9743211000 Walther Werke 9743211000 Harting Hella Wire 3 Wire 1 Wire 2 Walther Werke Eco Slim 32 A 9743205180 with connection cable 790000001 Wire 1 black Wire 3 blue Wire 2 red Phoeni...

Page 15: ...ster Master and slave configuration can be accessed via a selection page on the configuration website of the slave e g http 192 168 123 123 4 3 2 USB configuration interface CONFIG The USB configurati...

Page 16: ...f terminals WA and WB if the wiring is carried out in such a manner as to reduce the risk of a short circuit to a minimum A short circuit proof and earth fault proof wiring is recommen ded The connect...

Page 17: ...gnals between the electric vehicle and the charging station see IEC 61851 i i PP is not required if the charging cable is permanently attached 4 3 11 I O extension The charge controller features a con...

Page 18: ...nt panel The SIM card can have a PIN number which can be configured via the Settings tab The APN settings for the SIM card can also be configured via the Settings tab I I Caution Damage to the SIM car...

Page 19: ...11 2020 19 CC613 charge controller 4 3 16 Antenna socket The antenna socket allows connection to a 4G antenna not included in the scope of delivery i i The following approved antenna type must be use...

Page 20: ...r must be manually selected Open the device manager on the control panel Right click the RNDIS Ethernet Gadget menu item located at Other devices and select Update driver software Select the option Br...

Page 21: ...e g codes activation and resolution messages instructions and corrective measures OCCP configuration key for OCPP 1 5 and 1 6 e g key name and description Application of changed parameters Parameter...

Page 22: ...ler must be tested for operability This can be done us ing a vehicle simulator The following is checked Successful boot process OCPP state IDLE If intended establishment of backend connection connecti...

Page 23: ...e charge controller can be determined by assigning a fixed IP address at the DHCP server in your network This IP address can then be used to establish a connection In addition the charge controller al...

Page 24: ...em or included in the whitelist close to the RFID module the contactor is switched on and a current flow takes place The charge controller enables two modes of operation Authorisation BEFORE connectin...

Page 25: ...V Operating range of the nominal voltage DC 11 4 V 12 6 V Max nominal current 750 mA Max nominal current without USB load 400 mA Max nominal current with max USB load 750 mA Residual direct current m...

Page 26: ...micro USB port type AB SIM card only with 4G modem front panel micro SIM HMI terminal K internal Modbus meter terminal B 9 6 kBit External Modbus terminal I 9 6 kBit Control Pilot terminal B CP acc t...

Page 27: ...with plastic sleeve 0 14 0 75 mm AWG 26 18 Stripping length 10 mm Max connection cable length 2 m Cross section 0 5 mm2 Max connection cable length PE 4 m Cross section PE 1 mm2 Connection type termin...

Page 28: ...inien 2011 65 EU RoHS Richtlinie RoHS directive Directives 2014 53 EU RED Richtlinie RED directive Zur Beurteilung der Konformit t wurden folgende Normen herangezogen The assessment of this product ha...

Page 29: ...RJ45 cable length 500 mm B94060114 D00328 Measuring current transformerW15BS cable length 1450 mm B98080065 D00371 Measuring current transformerW15BS 02 cable length 180 mm B98080067 D00371 Measuring...

Page 30: ...2 Local access charge controller Chapter 4 1 Ext Modbus terminating resistor Chapter 4 2 2 Wiring diagram side view from right Chapter 4 2 2 Info on terminal I remote control Chapter 4 2 3 in table W...

Page 31: ...CC613_D00381_04_M_XXEN 11 2020 31 CC613 charge controller...

Page 32: ...r de www bender de All rights reserved Reprinting and duplicating only with permission of the publisher Bender GmbH Co KG PO Box 1161 35301 Gr nberg Germany Londorfer Str 65 35305 Gr nberg Germany Tel...

Reviews: