Technical data
32
CP9xx_D00349_08_M_XXEN/02.2022
Modbus TCP
Interface/protocol ................................................................................................................... Ethernet/Modbus TCP
Cable length................................................................................................................................................. < 100 m
Operating mode.........................................................................Client for PEM and "third-party devices" assigned
Operating mode........................................Server for access to process image and for Modbus control commands
SNMP
Interface/protocol ..............................................................................................................................Ethernet/SNMP
Versions............................................................................................................................................................1, 2c, 3
Supported devices ..................................................................................... query of all devices (channels) possible
Trap support ........................................................................................................................................................... no
Modbus RTU
Interface/protocol .................................................................................................................... RS-485/Modbus RTU
Operating mode...............................................................................................................................................master
Baud rate ....................................................................................................................................... 9.6…57.6 kbit/s
Cable length............................................................................................................................................... < 1200 m
Cable.....................................................................................................shielded, one end of shield connected to PE
recommended .................................................................................................... CAT6/CAT7 min. AWG23
alternative .............................................................................................twisted pair, J-Y (St) Y min. 2x0.8
Connection .................................................................................................... "AMB", "BMB" (see plug-in terminal)
Terminating resistor ..................................120 Ω (0.25 W), can be switched on internally (see plug-in terminal)
Supported Modbus RTU slave addresses .................................................................................................... 2…247
PROFINET
Interface/protocol ........................................................................................................................Ethernet/PROFINET
Operating mode............................................................................................................................... slave (IO device)
Digital inputs (1…12)
Number............................................................................................................................................................................. 12
Galvanic separation ......................................................................................................................................................... yes
Operating mode ................................................................................selectable for each input: active-high or active-low
Factory setting ....................................................................................................................................................active-high
Voltage range (high) .............................................................................................................................. AC/DC 10…30 V
Voltage range (low) .................................................................................................................................... AC/DC 0…2 V
Max. current per channel (at AC/DC 30 V) .................................................................................................................... 8 mA
Connection push-in terminal............................................................................................. (1-1) (2-2) (3-3) … (12-12)
Maximum cable length ....................................................................................................................................... < 1000 m
Switching elements
Number...................................................................................................................................................................... 1 relay
Operating mode ................................................................................................................ N/C operation / N/O operation
Function .......................................................................................................................................................programmable
Electrical endurance under rated operating conditions, number of cycles .............................................................10,000
Contact data acc. to IEC 60947-5-1
Utilisation category...............................................................................................................AC-13 / AC-14 / DC-12
Rated operational voltage .............................................................................................................24 V / 24 V / 24 V
Rated operational current....................................................................................................................2 A / 2 A / 2 A
Minimum contact load (relay manufacturer's reference)......................................................................10 μA / 10 mV DC
Connection ............................................................................................................................. plug-in terminal (11;12;14)
Buzzer
Buzzer message............................................................. can be acknowledged, adoption of characteristics of new value
Buzzer interval .................................................................................................................................................configurable
Buzzer frequency .............................................................................................................................................configurable
Buzzer repetition ..............................................................................................................................................configurable