Chew 4.6
kW
A
B
C
D
E
F
G
H
I
J
606mm
490mm 300mm 125mm 127mm 500mm 630mm 348mm 310mm 288mm
7
Stove Dimensions
Hearth
The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not
independently supported. The Chew stove is tested and suitable to be installed on a 12 mm non combus ble
plate such as 12mm glass plates. Installa on of all hearths should comply in size and construc on so that it is
in accordance with the provisions of the current Building Regula ons Approved Document J. The clearance
distances to combus ble material beneath, surrounding or on the hearth and walls adjacent to the hearth
should comply with the guidance on the separa on of combus ble material given in Building Regula ons
Approved Document J and also in these stove instruc ons. If the stove is to be installed on a wooden floor, it
must be covered with a non-combus ble material at least 12 mm thick, in accordance with Building Regula ons
Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the
door of the combus on chamber.
Combus on air supply
In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in
which the stove is installed to provide combus on air. This is par cularly necessary if the room is double-glazed
or a flue draught stabiliser is opera ng in the same room as the appliance. The provision of air supply to the
stove must be in accordance with current Building Regula ons Approved Document J. An opening window is
not appropriate for this purpose. Air inlets must be posi oned in such a way that they cannot be blocked. An
air inlet may be a vent (the vent must be open and the capacity for the vent sufficient when the stove is lit) .