Beltane Stoves Chew Multi-fuel Operation And Installation Manual Download Page 7

Flue Draught

In order for the stove to perform sa sfactorily the chimney height must be sufficient to ensure an adequate 
draught to clear the products of combus on and prevent smoke problems into the room. 

Stove Performance & Tes ng 

Chew 4.6 is tested in accordance with EN 13240. Chew is recommended as suitable for use in smoke  control 

areas  when  burning  wood  logs  and  when  fi ed  with  a  mechanical  stop  to  prevent  closure  of  the 

secondary/ter ary air control beyond :- Chew -2.5mm or 13% open posi on. 

Beltane

Output 

Range kW

CO@13%

Par culate ma er 

@13% mg/nm3

Nox @13%

CxHy@13%

2022 

Compliant

Chew

4-7 

0.05(W)/ 0.08(C)

25

120

57

YES 

Tested Gas flow rates flue 

gas temperatures

Flue gas flow rate 

Wood /coal

 Test Flue gas Temperature 

wood /coal

Pascals  Pressure

Chew 4.6 kW

4.3 /4.7 b/sec

231/221 Deg C

12pa 

Log Length

Wood 

Reload

Weight 

wood load Coal reload

Weight Coal 

(anthracite)

Length

SE dimensions 

LxWxD cm

Logs 

Chew 4.6 kW

35cm

25x14x11

1

1hr

1.2kg

2hr

1.4kg 

Output 

Wood /Coal

Efficiency wood 

/Coal

Recommended for 

smoke control

Mechanical air stop 

for SE Model

Mechanical stop 

on secondary

Chew 4.6 kW

4.6/ 4.9 kW

80.0/83.1%

 YES

YES

13%/2.5mm 

Distance to Combus ble materials

Combus ble materials should not be located where the heat dissipa ng through the walls of fireplaces or flues 

could ignite it. Therefore when installing the stove in the presence of combus ble materials due account must 

be taken of the guidance on the separa on of combus ble material given in  Building Regula ons  Approved

Document J and also in these stove instruc ons. The minimum distances to flammable materials are specified 

on the EN 13240 plate on the back of the stove. 

Distance to combus bles rear / rear 

with addi onal heat shield

Distance to combus bles sides

Suitable for 12mm hearth

300mm /150mm

500mm

YES 

There are no European rules regarding the minimum distance to non-flammable walls, Beltane recommend 
leaving a gap of at least 10 cm behind and to the sides of stove. 

Summary of Contents for Chew Multi-fuel

Page 1: ...OPERATION AND INSTALLATION MANUAL Wood Mul fuel SE models Chew Wood and Mul fuel Stove...

Page 2: ...of water PREPARATORY WORK AND SAFETY CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other hea ng appliance There must not be an extractor fan ed in the same r...

Page 3: ...remove the ue collar by unbol ng from the body of the stove 3 Break o tabs on rear convec on panel and remove the laser cut sec on To do this the rear convec on panel does not need to be removed 4 Re...

Page 4: ...the stove and place this in the hole in the top plate 197 5mm How to remove and install brick set 1 Remove log retainer 2 Remove base grate No 4 3 Remove base bricks No 5 2 o 4 Remove side brick le No...

Page 5: ...ve is ed in place of an open re the chimney should be swept one month a er installa on to clear any soot falls which may have occurred due to the di erence in combus on between the stove and the open...

Page 6: ...n adjoining or adjacent building whether or not beyond the boundary Note 3 at least 600mm above the adjacent building Notes 1 The weather surface is the building external surface such as its roof les...

Page 7: ...SE dimensions LxWxD cm Logs Chew 4 6 kW 35cm 25x14x11 1 1hr 1 2kg 2hr 1 4kg Output Wood Coal E ciency wood Coal Recommended for smoke control Mechanical air stop for SE Model Mechanical stop on secon...

Page 8: ...stove instruc ons If the stove is to be installed on a wooden oor it must be covered with a non combus ble material at least 12 mm thick in accordance with Building Regula ons Approved Document J to a...

Page 9: ...be burnt but par cular a en on should be taken of the weight loaded Make sure the load weight for wood is used when burning compressed wood For a full list of suitable fuels check with the o cial soli...

Page 10: ...purchase a smoke control version of the Beltane stove which is modi ed slightly to comply with regula ons Any change to this modi ca on will invalidate the stoves compliance for smoke control areas Th...

Page 11: ...and easier than using paper TO LIGHT YOUR STOVE Burning wood Note If the chimney is externally ed or the stove has been installed on a larger diameter clay chimney liner then on cold days it maybe nec...

Page 12: ...fuel see weight table on page 5 Do not overload Do not cover ter ary air ports see diagram page 13 Reloading is approximately every 2 hours 4 Close re door set primary air to 45 open and set secondary...

Page 13: ...r li handle To close push door closed and push handle down un l located The handle has push pull mo on When shu ng the door push the door closed and push handle rmly un l the door latches PARTS Always...

Page 14: ...ut Check the quality of all insulated panels and replace any which are damaged or cracked replace stove door rope cord in the door Check glass is correctly posi oned The stove the ue pipe connec on an...

Page 15: ...BELTANE CHEW BRICKSET ECO DESIGN 2022 15...

Page 16: ...himney dra b check for blockages in the ue pipe chimney c check the height of the chimney rela ve to the surroundings 6 Soot in the chimney a the rewood solid fuel may be too wet b intake of secondary...

Page 17: ...t our full range of Heating Products Central Heating Controls Honeywell Heating Controls Danfoss Heating Controls Radiator Valves Fernox Sentinel Magnaclean Warmup underfloor heating Water Heaters Han...

Reviews: