F.
Install Scale Support Pipes
This step is extremely important to ensure long term scale accuracy.
▪
The mounting pipe must touch the strap on the uphill side of load cell assembly.
▪
The strap on the downhill side must create an oval opening.
▪
Center the pipe in the oval hole.
▪
The load cell assembly must be free to move up and down slightly on the pipes.
This eliminates torque on the conveyor frame, which allows automatic alignment
of the weighing elements.
▪
Install the four hose clamps onto the pipe with the screw fitting directly over the
top of the pipe, but do not tighten the clamps at this time.
Uphill side
:
Retaining strap
fits tightly around the pipe.
Downhill side
:
Retaining strap
forms oval hole around the pipe.