background image

SYMBOLS

In this manual, on the labels, on the control panels of tbCOMPASS, following symbols are used. 

&RQ¿UPWKHPHDQLQJRIHDFKV\PERO

0197

Chair last position

Chair auto return

Chair preset1

Chair preset2

To raise the chair

To lower the chair

To Recline 

the backrest

To raise 

the backrest

Chair manual 

control

Chair auto control

To lower the chair

Handpiece coolant 

spray on/off

Fiber optic 

handpiece light

on//off

Micro motor 

Forward/Reverse 

select

Syringe

Dental light on/off 

Dental light

mode selection

Service outlet

water flow control

Service outlet 

(water)

Service outlet (air)

Water heater

Air

Authorized 

representative in 

the European 

community

Type B 

Applied Parts 

To Recline 

the backrest

To raise 

the backrest

Chair manual 

control

Handpiece Setting

Rotation mode 

select

Minus

Plus

Water

Function switch

Store switch

Bowl flush

Cupfiller

 Date of

 manufacture

Manufacturer

Protective earth 

(ground)

ON (power)

OFF (power)

Serial number

To raise the chair

Alternating current

Functional earth 

(ground)

Autoclave Symbol

This symbol on component means that the component 

can be sterilised with an autoclave at 135

 max.  

SN

Comply with

MDD,93/42/EEC

To lower the chair

To Recline 

the backrest

To raise 

the backrest

To raise the chair

Symbol          Description             Symbol          Description             Symbol           Description             Symbol           Description

Reference 

number

Serial Number 

SYMBOLS

Separate collection for electrical 

and electronic equipment 

Refer to instruction manual/booklet 

*The color of black part is blue in the actual label.

General warning, 

unspecified

*The base color is yellow

  in the actual label.

Basic precaution, 

unspecified

*The base color is yellow

  in the actual label.

Summary of Contents for tbCompass

Page 1: ...fter the installation has been completed keep this manual in a safe place and refer to it for future maintenance DENTAL UNIT AND CHAIR If you have any questions about this Manual or this product pleas...

Page 2: ...l panel 29 Vacuum handpiece 31 Saliva ejector handpiece 31 Spittoon bowl Rotation 31 Assistant control panel 31 Height adjustable assistant arm optional 32 Sensor cupfiller Optional 32 701 dental ligh...

Page 3: ...ieces In case of disposal of equipment When disposing the unit and chair appropriately dispose complying with all current applicable regulations and local codes In EU area EU directive 2002 96 EC on w...

Page 4: ...air manual control Handpiece Setting Rotation mode select Minus Plus Water Function switch Store switch Bowl flush Cupfiller Date of manufacture Manufacturer Protective earth ground ON power OFF power...

Page 5: ...face WARNING 1 Be sure to turn off breakers for equipment in the clinic when this product will not be used for a long period of time H VXUH WR WXUQ RII EUHDNHUV IRU HTXLSPHQW LQ WKH FOLQLF ZKHQ WKLV S...

Page 6: ...is in use Be sure to turn off the main switch when electrocautery is in use because noise may cause incorrect operation of this product Use this product with extreme caution on patients with a cardia...

Page 7: ...ring Please confirm whether a table is fixed If the table is not fixed surely it causes a fall and the accident during operation Make sure that water is poured into the cup before turning on the heat...

Page 8: ...irm that the patient is seated in the proper position Keep your eyes on the patient during the operation Pay special attention to surroundings at automatic operation of the dental treatment table Dama...

Page 9: ...ather of this product may become stained by direct contact with clothes or belts If there is stains wipe clean as quickly as possible with a 10 detergent solution diluted using water to prevent perman...

Page 10: ...surface of the operation panel 26 Precautions for cleaning of the spittoon bowl The spittoon bowl is made of glass or ceramic optional It may break if it is impacted Do not wash it with hot water Othe...

Page 11: ...ng the vacuum saliva ejector handpiece and syringe Cleaning must be done within 1 hour after use Replace with a new vacuum handpiece and saliva ejector handpiece for following cases Any waste material...

Page 12: ...d air are intended to increase decrease the flow rate but do not serve as stop valves Caution should be exercised as tuning the knob excessively may cause it to turn free 3 Handling of the single arti...

Page 13: ...4 5 Take care not to be trapped by moving parts of the headrest R QRW DOORZ KDQGV QJHUV RU KDLU WR EHFRPH HQWDQJOHG in the moving parts of the headrest Take care not to be trapped by the lower part o...

Page 14: ...6 ULQJH RFWRU TDEOH XVSLGRU Cuspidor line XS OOHU ZDWHU KHDWHU RZO XVK OXVKRXW SURFHGXUHV IRU FXVSLGRU OLQH SOHDVH UHIHU WR 3DJH VHOHFWLRQ IRU RSHUDWLRQ RI XVKRXW 0RGH 3URFHGXUH RI XVK RXW Standard P...

Page 15: ...ction Doctor Table Doctor Unit Section Spittoon Glass or ceramic optional Headrest Backrest Armrest 11 Overview and Major Components Standard Package Doctor Arm Assistant s Holder Doctor Table Doctor...

Page 16: ...nel Handle Doctor Instruments Holder Place Holder Type Doctor Unit Section 12 OVERVIEW AND MAJOR COMPONENTS Cuspidor Maintenance Panel Solid Collector Assistant Control Panel Assistant Instruments Hol...

Page 17: ...kwise to close Drain valve Drains the water collected at the air lter on the main water supply line Fuse holder The main fuse of units is built in Turn off the main switch when replacing the fuse The...

Page 18: ...t The headrest will be come off from the backrest in case of pulling too much R QRW DOORZ KDQGV QJHUV Rr hair to become entangled in the moving parts of the headrest 1 Height Adjustment Hold the headr...

Page 19: ...ONENTS NOTICE 1 Chair Section The headrest will be come off from the backrest in case of pulling too much R QRW DOORZ KDQGV QJHUV Rr hair to become entangled in the moving parts of the headrest Manual...

Page 20: ...tically Momentarily press the switch will lower the chair and raise the backrest to the initial position Momentarily press the switch with the chair in the treatment position moves the chair to the ri...

Page 21: ...error message is still displayed please contact your dealer or our of ce This doctor unit section is actuated by compressed air Therefore ensure that the air compressor is working S y r i n g e Syrin...

Page 22: ...e operable handpiece is displayed on the indicator If multiple handpieces are picked up in succession from the holder and the handpiece that was picked up UVW is returned to the holder error display E...

Page 23: ...witch for on off of handpiece coolant spray Handpiece light switch Switch for turning on the handpiece fiber optic light Chair motion lock indicator lamp This indicator lamp is lit while chair motion...

Page 24: ...the chair is in motion Last Position Switch Momentarily press the switch with the chair in the treatment position moves the chair to the rinsing position and another press of this switch returns the...

Page 25: ...ded by dotted lines Assistant control panel To stop the chair automatic movement press any of switches surrounded by dotted lines Foot controller To stop the chair automatic movement by pressing shade...

Page 26: ...ushing Cup ller switch Water is supplied through the cupfiller nozzle when this switch is pressed Simultaneous with start up of cupfiller motion water comes out of the bowl ush nozzle and ushes the c...

Page 27: ...between spray both of LED A and LED W are lit and OFF occurs when this switch is pressed In case of electric scaler switching between water only LED W is lit and OFF occurs when this switch is presse...

Page 28: ...tation Forward rotation is preset power is on In case a micromotor set for reverse rotation is returned to its holder the LED indicates forward rotation When such a micromotor is picked up however the...

Page 29: ...tion 7 Micromotor limit rotation speed selection 8 Micromotor spray mode selection 9 Cup ller and bowl ush interlocked action selection Function of calculating and displaying the micromotor gear ratio...

Page 30: ...ode Limit speed SET1 SET2 SET3 Limit speed Operation and display of scaler When the electric scaler is picked up from the holder the selected mode is displayed on the indicator either PERIO ENDO or SC...

Page 31: ...itch Front Arm Collar Lock ring Groove for height adjustment Screen Screen QWUD RUDO VL H OPYLHZHr Optional The screen light is lit when the switch is pressed and the screen light is off when the swit...

Page 32: ...nel on the table 4 mode Water Air OFF Spray operation can be selected for the motor Chip Brow Switch Chip air for blowing off the chips jets out of the handpiece when the chip blow switch is depressed...

Page 33: ...e knurlet screw from bottom of the cuspidor unit Vacuum Package 1 Dental light select switch This switches changes the lighting mode SENSOR MANUAL OFF of the dental light There are cases where this sw...

Page 34: ...WKH RZ UDWH RI ERZO XVK 7KH RZ UDWH GHFUHDVHV ZKHQ WKH NQRE LV WXUQHG FORFNZLVH DQG WKH RZ UDWH LQFUHDVHV ZKHQ WKH NQRE LV WXUQHG FRXQWHUFOockwise 8 Syringe water control 0DNH DGMXVWPHQW RI V ULQJH ZD...

Page 35: ...ure that the patient does not lean on the cuspidor unit as pushing on the spittoon bowl causes it to swing outwards Assistant control panel The operation and functions of the assistant contril panel a...

Page 36: ...nly an empty cup using a cup with some water left FDQ FDXVH DQ RYHU Rw 7KH VHQVRU FXS OOHU QHHGV RYHU VHFRQGV LQWHUYDO EHWZHHQ FXS OOLQJ Use only suitable disposable paper cup dental paper cup 5 oz Ma...

Page 37: ...ity are available as shows on the left The intensity changes when you press up the rubber cover of the intensity switch from below Changing into composite mode When the main switch of the dental unit...

Page 38: ...om the touchless switch surface It goes out when you shake your hand again If the surface of a touchless switch becomes unclean this may affect the sensitivity of the sensor Please wipe the surface of...

Page 39: ...ensity between 3 100 28 000lx by stepless LQWHQVLW FRQWURO YROXPH DV OHIW JXUH The intensity is increased by turning intensity control volume clockwise It is decreased by turning the intensity control...

Page 40: ...injury Take care not to pinch the vacXXP hose and saliva ejector hose Eetween the assistant arP and the cuspidor VZLQJ DUP GXULQJ WKLV ZRUN NOTICE When the lock lever B is GLI FXOW to pull At that WLP...

Page 41: ...ket to make easier to pull out the lock lever A Be carefully when moving the cuspidor unit Not to contact the cuspidor unit with the doctor table Swing the doctor table to the cuspidor side as shown o...

Page 42: ...the left JXUH When the cuspidor unit moved to correct position as shown on the left JXUH the lock lever A on the swing bracket can be locked automatically 8 Turn the lock lever B to change the positi...

Page 43: ...ck lever C Pull the lock lever C on the swing arm bracket then swing the light pole slightly to chair legrest side 11 Lift the toe board of seat cushion and swing the light pole to other VLGH DV VKRZQ...

Page 44: ...B After this conversion be sure to confirm the safety function has been working properly Please refer to the next page After moved the light pole the balance arm position become A position as shown o...

Page 45: ...hair motion works while of the following actions is taken The LOCK LED indicator lamp is lit in orange in this state on the doctor control panel Refer to page_51 for chair motion stop function If exce...

Page 46: ...and setup has been completed 3 To change the set position perform the procedures steps 1 and 2 above Set the treatment position by chair manual switch Keep pressing preset switch to be set for about...

Page 47: ...tion switch setup are described below Normal action is restored during setup if the next operation is not applied within about 10 seconds Setup and operation of dental timer Selection of doctor number...

Page 48: ...increases continuously when the switch or switch is pressed and held 3 Press store switch 4 Press one of chair preset switches to store the set timer to a particular preset number When change the pres...

Page 49: ...g time If you want to change setup of the light pack residual lighting time please contact your dealer or our of ce 3 Selection and operation of ushout Procedure for operation Mode I Case of ushout of...

Page 50: ...andpiece light on timing can be selected from the two mode 1 Rotation mode FOOT The light is turned on while the handpiece is running and is off upon elapse of the set light remaining time after termi...

Page 51: ...switch 5 steps switch 8 Selection of micromotor spray mode Case of 2 modes Micromotor spray on off only Case of 4 modes Micromotor spray on off water only and air only Procedure for setup 1 Press the...

Page 52: ...the switch or switch The numerical value displayed on the indicator changes 5 To store the rotation after change press the switch The set value before change is restored if the main switch is off wit...

Page 53: ...isplayed as GEAR x 1 is constant speed mode 2 Press the or switch to select gear ratios High speed Low speed 3 Press the store switch to save it During the setting press the function switch once to ca...

Page 54: ...owever there is a possibility where reset does not occur if noise is continuing Eliminate the cause for the noise and then turn on the power again If it is not possible to identify the cause for the n...

Page 55: ...ward reverse select switch ickers in orange in this state DQG WKXV LQGLFDWHV WKDW WKH VDIHW PHFKDQLVP LV ZRUNLQJ Make VXUH to pick XS a handpiece UVW and then depress the foot controller for operation...

Page 56: ...hat the main water pressure gauge reads a value between 0 1 and 0 2 MPa Be sure to press the knob to lock it after setting This knob is adjusted when installing the unit Do not change the setting unde...

Page 57: ...tion may be accelerated Do not use solvent and bleach Use FD366 made by Durr for cleaning and disinfection of the product exterior Apply dry wiping using a dry and soft cloth to metallic and resin cov...

Page 58: ...lave sterilization the tray may is subject to discoloration which does not have a negative effect on performance Do NOT spray directly Doctor control panel In case the surface of the doctor control pa...

Page 59: ...hol or the like Observe instructions given in handpiece instruction manuals for the care of handpieces Oil mist separator Optional The oil mist separator collects oil contained in exhaust air from the...

Page 60: ...In order to prevent damage to electrical components and system Use FD333 or FD366 made by Durr or ethanol as sprayed to a soft cloth for cleaning and disinfection Wipe off with dry soft cloth to drie...

Page 61: ...jects during cleaning may produce discharge of water including bowl rinse water leading to rusting of metals The spittoon bowl is made of glass It may break if it is impacted Do not wash it with hot w...

Page 62: ...oove and OWHU E D FOHDQLQJ EUXVK RU E D WRRWK EUXVK ZLWK UXQQLQJ clean warm water at 40 5 degrees Wipe off by a cloth for the area which brush is unable to reach 2 Check whether contamination is remov...

Page 63: ...135 C or less 7KH FDS OWHr and body are made of resin They may become deteriorated if they are sterilized in an autoclave many times After DXWRFODYH VWHULOL DWLRQ WKH FDS OWHr body and valve are subj...

Page 64: ...the solid collector and clean with running water The lter is expendable supplies If damage occurs to the OWHr UHSODFH ZLWK QHZ OWHr CAUTION OHDQ WKH OWHr carefully with running water R QRW XVH EUXVK W...

Page 65: ...end to use ID212 made by DURR 4 Rinse thoroughly by distilled water at ordinary temperature or by clean water for more than 1 minute A B w A Syringe body Nut Nozzle Assembly Sterilization pouch Steril...

Page 66: ...drain valve of the air compressor to discharge collected water once a week It is recommend that the compressor with air dryer or auto drain function for use Turn OFF the main water valve after daily o...

Page 67: ...l maintenance have different durability periods See the section on maintenance and inspection Stock period of parts Our company will keep maintenance parts of the products such as consumables and peri...

Page 68: ...ed Power of the vacuum pump has not been turned on Turn on the power Solid collector lter is contaminated Clean the lter Vacuum handpiece lter is contaminated Clean the lter Saliva ejector does not su...

Page 69: ...equipment Applied part type B applied part Seat for chair Handpieces for unit List of compatible handpieces Usage environment Temperature 0 to 40 C Humidity 10 to 95 Air pressure 700 to 1060 hPa Trans...

Page 70: ...rt type B applied part Seat for chair Handpieces for unit List of compatible handpieces Usage environment Temperature 0 to 40 C Humidity 10 to 95 Air pressure 700 to 1060 hPa Transportation Storage en...

Page 71: ...part Seat for chair Handpieces for unit List of compatible handpieces Usage environment Temperature 0 to 40 C Humidity 10 to 95 Air pressure 700 to 1060 hPa Transportation Storage environment Temperat...

Page 72: ...uipment Applied part type B applied part Seat for chair Handpieces for unit List of compatible handpieces Usage environment Temperature 0 to 40 C Humidity 10 to 95 Air pressure 700 to 1060 hPa Transpo...

Page 73: ...of dark color or pattern Cupfilling may not be executed Execute re inspection in accor dance with Method for operation described in the instruction manual Contact your dealer or our office if recover...

Page 74: ...roduced from product s moving parts when the product is operated The product will not normally work and troubles may arise Contact your dealer or our office if any abnormality arises Care Drain valve...

Page 75: ...tandard Lifetime No 3 years 1 2 3 years 3 5 years 3 years 3 4 4 5 3 years Consumable parts No Parts Description 1 2 Parts Description Standard Lifetime No 3 years 8 9 3 years 10 5 years 5 years 11 12...

Page 76: ...IR BORA S36L UNIFIX w Light BIEN AIR Aquilon 830 UNIFIX w Light PM1132 BIEN AIR MX2 VARIOS170 NSK BTK 77 TYPE FARO 3WAY LUZZANI 3WAY LUZZANI 6WAY DCI 3WAY BIEN AIR DMCX MCX NSK NLX plus Syringe Turbin...

Page 77: ...1 0 UT 0 5 cycles 0 45 90 135 180 225 270 and 315 0 UT 1cycle and 70 UT 25 30 cycles at 0 single phase 0 UT 250 300 cycles 0 UT 0 5 cycles 0 45 90 135 180 225 270 and 315 0 UT 1cycle and 70 UT 25 30 c...

Page 78: ...uding peripherals such as antenna cablesand external antennas should be used no closer than 30 cm 12 inches to any part of the tbCOMPASS including cables specified by the manufacturer Otherwise degrad...

Page 79: ...on category 8 of Annex I Product DENTAL UNIT AND CHAIR CLASS IIa Model tbCOMPASS 66 D KDV EHHQ GH QHG E WKH UXOH RI 0 QQH The product has been designed and manufactured in accordance with the Europea...

Page 80: ...542 0083 Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION BOOK NO 1A0AAKPE Printed in Japan 2019 12 TAKARA COMPANY EUROPE GmbH Berner Strasse 18 60437 Frankfurt am Main Germany...

Reviews: