4

F)

 

To program the alarm relay

1)

 

Enter program mode by pressing: * 5 *  (green LED will light up, and two
shorts beeps are heard from the buzzer)

2)

 

Press: 1 (green LED will start flashing)

3)

 

Set the alarm relay function 1-3:
Press 1 for relay activation when alarm A is activated
Press 2 for relay activation when alarm B is activated
Press 3 for relay activation when alarm A or B is activated

4)

 

End by pressing #

5)

 

Set how long the relay should be on (minutes) after activation:
Press 0-60 (If no activation press 0)
Press #  (the green LED will be continuously on, and the buzzer will give two
short beeps)

6)

 

Press 0 to leave the program mode, alternatively program Telephone
numbers/Alarm input (C2 above), or ID speech program (E2 above)

ACKNOWLEDGEMENT OF AN ALARM

A)

 

On the keyboard

Press the digits

B)  By telephone

When by telephone receiving an alarm the user can make an acknowledgement
by pressing *0#. The alarm will then confirm by speech the received
acknowledgement and disconnect the telephone line.

BASIC RESET

A basic reset (total reset) that will erase any telephone numbers in the memory,
set the ID codes to 0, and set the relay activation when any alarm input is
present to 1 minute.

Disconnect the alarm transmitter from the power. Press and hold the buttons 4,5,
6 and connect the power. Continue to press the buttons until two beeps are heard
and the green lED will light up.

© Ondico AB 2002-03-04

C:\

 

DOKUMENT\PRODUKTINFO\OND-9005