Abnormal conditions include: 

Excessively yellow or sooting flame type.

Flame lifting off the burner ports.

Flame lighting back into the burner (normally associated with a popping sound).

Objectionable odour of the flames combustion products.

Should a faulty condition develop in the hotplate that is not described above, refer to the following table first for possible causes 
and  remedies  prior  to  contacting  an  authorised  service  representative.  Servicing  beyond  the  remedies  listed  shall  only  be 
undertaken by an authorised service representative.  

FAULT

 

POSSIBLE CAUSE

 

REMEDY

 

No spark when gas control 
knob depressed.  

No power. 

Check plugged in and switched on. 
Check mains circuit breaker.  

Loose sparker cable. 

Call authorised representative. 

Burner not aligned properly. 

Remove and re-fit burner. 

Burner  not  lighting  when 
spark ignition working.  

Gas supply off. 

Check gas supply valve on. 

Burner not aligned properly. 

Remove and re-fit burner. 

Burner ports blocked. 

Remove, clean and replace burner. 

Burner  goes  out  when 
control knob released.  

Flame safeguard not activated. 

Re-light, allow more time for flame safeguard 
to activate.  

Flame safeguard faulty connection or 
broken.  

Call authorised representative. 

Uneven  flame  pattern  or 
slight flame lifting.  

Burner ports blocked. 

Remove, clean and replace burner. 

At minimum flame, setting 
the flame is too high.  

Turndown control setting incorrect. 

Call authorised representative. 

Small 

flame 

on 

High 

setting.  

Regulator faulty. 

Call authorised representative. 

Gas supply pressure low. 

Call authorised representative. 

Incorrect injector fitted. 

Call authorised representative. 

Blocked injector or gas supply tube. 

Call authorised representative. 

Incorrect utensil size. 

Refer to operating instructions utensil choice. 

Flame  too  high  on  High 
setting.  

Regulator faulty. 

Call authorised representative. 

Incorrect injector fitted. 

Call authorised representative. 

Incorrect utensil size. 

Refer to operating instructions utensil choice. 

14 

Summary of Contents for BGT64XP

Page 1: ...op Model No BGT64XP W BGT64XP F BGT64XP FINELINE 81477 V6 NOV20 GSM Retail Australia Pty Ltd ABN 53 007 582 475 For Warranty and technical queries 1300 373 199 Aus Or 0800 764 912 NZ www belliniapplia...

Page 2: ...In Home warranty be sure to retain your installation and user manual and receipt For all warranty and technical queries please contact 1300 373 199 GSM Retail Australia Pty Ltd ABN 53 007 582 475 For...

Page 3: ...7 Start using your appliance 11 Maintenance and Troubleshooting 13 Warranty 23 GSM Retail Australia Pty Ltd ABN 53 007 582 475 For Warranty and technical queries 1300 373 199 Aus Or 0800 764 912 NZ ww...

Page 4: ...l connections must be made by specialist installers to the legal and regulatory requirements in each country If the cable is damaged in any way it must be replaced by the manufacturer or after sale se...

Page 5: ...that are switched on Risk of burns Do not place objects made of metal such as knives forks spoons and saucepan lids on the cooking surface as they can get hot Special conditions which shall be avoided...

Page 6: ...f an under bench oven How to Avoid Damage to the Appliance Do not use the cooking zones with empty cookware or without cookware The ventilation gap of 5mm between the worktop and front of the unit und...

Page 7: ...view 1 BGT64XP BGT64XP and all variations of model 1W 2SR 1A With 2 types for option Front LPG 30 5MJ h NG 29 5MJ h NOTE On completion of the installation of the cooktop to the kitchen bench the dist...

Page 8: ...g label in accessory bag suggest attach it onto a surface where it can be read e g inside surface of adjacent cupboard 1 set Installation clip 4 sets Screws ST4 x24 4 pcs LPG Injectors 4 pcs Elbow Was...

Page 9: ...le hose connection with the hotplate in the installed position Before the appliance is installed into the cabinet please make sure any transit protection is removed NOTE This appliance is built in app...

Page 10: ...ed correctly it will not rotate on its supports The Triple Ring Wok burner diagrams below does not fit over the igniter or thermocouple but must be placed on its supports Make sure trivet is fitted on...

Page 11: ...sembly shall be suitable for connection to a fixed consumer piping outlet located as follows Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of the appliance...

Page 12: ...10...

Page 13: ...iations of model ADJUSTED FOR NATURAL GAS 1 0kPa ADJUSTED FOR ULPG 2 75KPa NOZZLES DIAMETER mm Gas consumption MJ h NOZZLES DIAMETER mm Gas consumption MJ h WOK 1 70 13 0 WOK 0 98 13 0 SEMI RAPID 1 10...

Page 14: ...rsist refer to the TROUBLESHOOTING section of these instructions If power is not available light a match or similar then turn the gas control knob for the burner to be lit to the High Flame setting On...

Page 15: ...ive products Rinse with clean water Dry with a clean soft cloth BURNERS Remove trivets from hob Ensure burners are cool Remove the burners enameled cap C and aluminum burner crown F Wash down with war...

Page 16: ...cuit breaker Loose sparker cable Call authorised representative Burner not aligned properly Remove and re fit burner Burner not lighting when spark ignition working Gas supply off Check gas supply val...

Page 17: ...the Bellini product or it fails to perform to the Company s specifications as a result of some defect in materials components or workmanship Defect then the Company will at its option repair the Belli...

Page 18: ...any determines that it is defective through no fault of the Owner and is otherwise undamaged the Company will repair or replace the Bellini product in accordance with thiswarranty DO NOT SEND IN THIS...

Reviews: