2.3 PREPARATIONS BEFORE INSTALLATION
Before installing the appliance, fi rst observe the following instructions.
2.3.1 The most important facilities according to the regulations
1
NATURALLY VENTILATED HOUSE (see Figure 6).
• The room in which the appliance is to be fi tted must have a non-
closable combustion air supply opening. The minimum dimensions
are detailed in “Technical Details/Regulations” at the rear of this
manual (see also Paragraph 2.4, point 2).
• The fl ue gas exhaust must exit at “outlet area
I
”.
OUTLET AREA
I
AIR SUPPLY
OPENING
GAS
Figure 6: Naturally ventilated house