47
Bell
fi res
English
Installation instructions
3 MAINTENANCE
3.1 ANNUAL MAINTENANCE
It is essential that the appliance, the complete
concentric fl ue system (where possible) and the
outlet are cleaned and inspected annually by a
recognised fi tter/gas specialist.
The safe operation of the appliance will thus
remain guaranteed.
Maintenance consists of the following:
• Remove fi rst the embers, ‘Fire glass’, decorative ash and the logs set from the main
burner and carefully clean these with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber,
fl ue system and combustion air intake. Dust can be removed using a vacuum
cleaner.
• Clean the glass on the inside of the appliance with glass spray or ceramic hob
cleaner
. This also applies to the black mirror rear wall, if the appliance is fi tted with
these.
• After cleaning;
Carefully replace the embers, ‘Fire glass’, decorative ash and the logs set on and
around the main burner according to the installation directions in this instruction
booklet.
Do not place any embers, ‘Fire glass’, decorative ash or logs against the pilot
light burner. Make sure that the pilot fl ame can burn at all times freely over the
main burner. Only in this way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, fl ue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple circuit and the
ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns at
maximum) and the burner pressure.
• Check the complete concentric fl ue system including the outlet construction.
A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake.
Also check that all connections are secure.
Summary of Contents for Smart Bell 70 PF
Page 2: ......
Page 6: ...6 Bell res English Installation instructions...
Page 32: ...32 Bell res English Installation instructions Fire glass Dark Amber Embers E Decorative ash A...
Page 54: ...54 Bell res English Installation instructions 7 DIMENSIONS 7 1 SMART BELL 75 70 Built in Frame...
Page 55: ...55 Bell res English Installation instructions 7 2 SMART BELL 75 70 Classic Frame 35 mm...
Page 56: ...56 Bell res English Installation instructions 7 3 SMART BELL 75 70 Classic Frame 52 mm...
Page 57: ...57 Bell res English Installation instructions 7 4 SMART BELL 75 70 Classic Frame 70 mm...
Page 58: ...58 Bell res English Installation instructions 7 5 SMART BELL 75 70 Deepened Frame...
Page 66: ...66 Bell res English Installation instructions...
Page 67: ......