background image

IInstallation and

maintenance manual

Smart Bell 65/55 MF

Serial number:

Production date:

Summary of Contents for Smart Bell 55 MF

Page 1: ...I Installation and maintenance manual Smart Bell 65 55 MF Serial number Production date...

Page 2: ...without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document fr...

Page 3: ...7 5 Overview of the fan light module 15 3 Safety 16 3 1 Safety devices on the appliance 16 3 2 Safety instructions for installation 16 3 3 Safety instructions with regard to the environment 17 4 Inst...

Page 4: ...niFire GB IE ES IT 31 7 2 Diagram electricity and gas 33 7 3 Dimensions Smart Bell 65 55 with a Built in frame 34 7 4 Dimensions Smart Bell 65 55 with a Classic frame 35 mm 35 7 5 Dimensions Smart Bel...

Page 5: ...ypical setup The illustrations are for instructional use only 1 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter in de...

Page 6: ...or as a built in appliance in a new replace The appliance can be installed with a convection fan set The convection fan collects the heated convection air from the appliance and releases this air int...

Page 7: ...erview of the appliance Item Description A Glass The heat resistant glass keeps the flue gas ses inside the appliance and closes the com bustion chamber off B Burner bed Top side of the gas burner and...

Page 8: ...ing L Hook For opening the door including glass 2 5 Overview of the burner bed and the pilot light Item Description A Grate Combustion air gets in the combustion cham ber through the grate around the...

Page 9: ...2 2 6 Overview of the ceramic log set No Ember grate No Ember grate with pilot opening 3T 3TV 3T 3T No Fire glass Dark Amber No Embers No Log No Charcoal 1 21 2 22 Description Smart Bell 65 55 9...

Page 10: ...N No Log No Charcoal 4 25 6 No Wood chip No Wood chip P70 6 P70 7 P70 6 Description 10 Smart Bell 65 55...

Page 11: ...Gas connection for the front burner The connection for the front burner gas pipe E Adjustment screw for the minimum burner pressure sets the minimum burner pressure The ad justment screw is factory s...

Page 12: ...factory set and sealed B Adjustment screw maximum burner pressure Sets the maximum gas pressure for the burn er The adjustment screw is factory set and sealed C Motor knob Operates the internal main g...

Page 13: ...the thermocouple signal is weak or broken the gas supply to the pilot light will stop E Connector Connects the gas valve of the rear burner F Gas pipe rear burner Supplies gas to the rear of the main...

Page 14: ...n Connection to the thermoelectric pilot light shut off wire OUT G Piezo cable connection Connection for the piezo cable which is con nected to the ignition electrode of the pilot light H Connection t...

Page 15: ...d plug Connection is also used for earthing the appliance B Connection for a convection fan Powers the convection fan Optional for this appliance C Connection for the ambient lights Powers the ambient...

Page 16: ...installation instructions and the national and the local applicable regulations Do not put flammable materials in the fireplace Make sure that the area around the fireplace is free of flammable mater...

Page 17: ...produce pungent odour and can produce discolouration of the fireplace Make sure that brickwork is build with a clearing of at least 3 mm between the sides and the top of the appliance and the brickwor...

Page 18: ...cedures in this section Optional procedures are indicated with optional 4 2 1 Install the appliance Safety conditions Caution Do not install the appliance against a flammable rear wall Procedure 1 Ins...

Page 19: ...sure that you do not damage the gas supply pipe 1 Connect the gas to the appliance Use a compression fitting 2 Make sure that the gas is correctly connected 4 2 4 Do a check on the gas connections Mak...

Page 20: ...aration manual Baffle plate C stays in place when a restriction plate must be installed 4 2 8 Remove the baffle plate The appliance is factory supplied with a baf e plate This baf e plate is located a...

Page 21: ...sing without the use of a mantel iron Note Make sure that the thickness of any plastering is taken into account when the brickwork is being build If you use other material than bricks install the mate...

Page 22: ...grates can lead to a dangerous situation Put the items of the log set in the correct configuration for the type of gas burner If you put the items of the log set in another configuration a dangerous...

Page 23: ...s the same everywhere Adjust the distribution of the re glass if necessary 4 Spread the embers evenly behind and beside the burner bed Caution Do not apply embers on the openings of the ember grates E...

Page 24: ...needs to harden A final check on the fireplace can be done directly after the installation Procedure 1 Start the appliance and do a check on the ignition of the pilot light and main burner The igniti...

Page 25: ...light burner and the flue system 5 Remove the grate 6 Clean the combustion air intake a Clean the combustion air intake A at the bottom sides of the appliance b Clean the primary combustion air inlet...

Page 26: ...when the appliance is off and when the appliance burns on maximum Refer to 7 for the required supply pressure and burner pressure 5 Make sure that the ambient lighting operates correctly Refer to the...

Page 27: ...ncluding glass Caution Make sure that the door with the glass pane fits properly in the appliance and seals the inside of the appliance If the door does not fit properly there is a risk of flue gas le...

Page 28: ...of the front The door must t tightly all round to the edge of the combustion chamber Make sure that the spring strip on the top remains in it s proper place 5 2 3 Remove the frame 1 First remove the d...

Page 29: ...ts can leave a mark on the glass 5 2 6 Replace the ambient light bulb when broken 1 Turn off the power supply to the appliance 2 Remove the content from the burner bed 3 Remove the grate 4 Carefully u...

Page 30: ...oes not react on the remote control The batteries of the remote control are empty Replace the batteries Refer to the user manual The pilot burner stops to burn There is insufficient exhaust of the flu...

Page 31: ...et Calorific Value NCV at nominal heat output 88 3 89 9 Useful efficiency Net Calorific Value NCV at minimum heat output indicative 82 7 86 6 NOX max Gross Calorific Value GCV 130 mg kWhinput 130 mg k...

Page 32: ...ctricity consump tion at minimum heat output 0 kW 0 kW Auxiliary electricity consump tion in standby mode 0 kW 0 kW Weight Basic model 56 kg 56 kg Including Storage module 59 kg 59 kg The specific pre...

Page 33: ...mbient lighting G Gas pipe rear burner H Gas pipe front burner I Gas supply connection J Pilot light burner K Pilot light pipe L Piezo cable M Thermocouple N Thermocouple interrupter O 8 wire cable P...

Page 34: ...7 7 3 Dimensions Smart Bell 65 55 with a Built in frame Technical specification 34 Smart Bell 65 55...

Page 35: ...7 7 4 Dimensions Smart Bell 65 55 with a Classic frame 35 mm Technical specification Smart Bell 65 55 35...

Page 36: ...7 7 5 Dimensions Smart Bell 65 55 with a Classic frame 52 mm Technical specification 36 Smart Bell 65 55...

Page 37: ...7 7 6 Dimensions Smart Bell 65 55 with a Classic frame 70 mm Technical specification Smart Bell 65 55 37...

Page 38: ...7 7 7 Dimensions Smart Bell 65 55 with an Insert frame 15 mm Technical specification 38 Smart Bell 65 55...

Page 39: ...7 7 8 Dimensions Smart Bell 65 55 with an Insert frame 50 mm Technical specification Smart Bell 65 55 39...

Page 40: ...Insert frame 50 mm and Convection fan 7 10 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection 100 150 Roof mounted outlet 30 40 50 65 T...

Page 41: ...le after they have manifested themselves 3 Complaints will only be accepted if they are reported to the Bellfires dealer together with the serial number of the Bellfires appliance which is stated on t...

Page 42: ...rranty does not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warra...

Page 43: ...9 9 EU Declaration of Conformity EU Declaration of Conformity Smart Bell 65 55 43...

Page 44: ...Y Your Bellfires dealer 001 10 04 2018 347179...

Reviews: