33
Safety
3.1
Safety devices on the appliance
Name
Description
Thermo-electric pilot light shut off
Prevents unforseen discharge of gas from the main
burner.
Overpressure door
If an overpressure occurs in the appliance, the door
opens for a short duration. When the door opens, a
loud noise can occur. If an overpressure occurs, the in-
staller must do a thorough check on the appliance.
3.2
Safety instructions for installation
Warning:
• The appliance must be positioned and connected as a 'room sealed
system' appliance by a certified and registered gas installation engineer
• Before beginning the installation, check that the details on the rating plate
correspond to the gas type and supply pressure to which the appliance will
be connected.
• Install the appliance in accordance with the following installation
instructions, and the national and the local applicable regulations.
• Do not put flammable materials in the fireplace.
• Make sure that the area around the fireplace is free of flammable materials
at all times. the minimal safe distance is 100 cm from the fireplace.
• Make sure that the burner openings stay clean during installation.
Blockage of the burner openings can lead to a dangerous situation.
• Make sure that the gas regulator block and the piping remain free of
cement or other building material. Otherwise, the gas regulator block or the
piping can start to leak.
• Do not twist the flexible pipes to the gas regulator block. Make sure that
there is no stress on the flexible pipes and the gas regulator block.
• Make sure that you do not damage the pipes.
• Make sure that the compression fittings do not come loose.
• Do not install the appliance against a flammable rear wall.
• After installation, Make sure that the pipes and compression fittings are
gas tight.
Safety
16
Smart Bell 65-55