The appliance can be built in using brickwork or by means of fire-resistant plates that
are screwed to a metal frame. You can, if you like, erect a natural stone mantelpiece in
front of this.
Note ! :
Ensure that there is a clearence of 2 mm between the brick work/fireproof
plate in connection with the appliance expanding when hot.
Convection set (2x) is optional.
Now connect the flexible hoses to the 4 convection openings (Ø125 mm) on the top of
the fire and to the metal fitting box on the air grills that are being used (do not forget to
fit hose clamps).
Insulate the convection casing with high-temperature resistant unbound insulation
material. The hot-air flexible hoses must also be adequately insulated. The blow-out
grids (min. 450 cm
2
) cannot be fitted until a few days later, once the masonry has been
pointed and allowed to dry. If one or more channels are connected leading to other
rooms, these rooms must be fitted with closable grids. These are available from your
dealer, as well as the flexible hoses and clamps required.
Ensure that the hose connections are gastight and that the whole flue is gastight and
insulated. After four weeks, your fire will be ready for use.
COLEUR
DIAMETER (cm)
CLEAR OPENING (cm
2
)
White
13,5 x 13,5
75
(incl. box)
White
27,0 x 13,5
150
(incl. box)
White
43,0 x 22,0
550
GRIDS
Place a length of pipe (Ø125 mm) with a moveable valve between the collar ring and
the “outside air supply opening in the wall/floor”; the rod with the operating knob must
be built in in such a way that the valve can be opened and closed from the living area.
Fit, if necessary, a flexible aluminium or stainless steel pipe between the “collar ring”
and “pipe with valve”, and between the “pipe with valve” and the “outside air supply
opening”.
Check that everything works correctly.