![Belle Group Premier XT Operator'S Manual Download Page 11](http://html.mh-extra.com/html/belle-group/premier-xt/premier-xt_operators-manual_2729109011.webp)
11
3.
YANMAR (RECOIL START) Back Up to Electric Start
STOPPING
3.9 Press red lever (Fig D).
EMERGENCY STOP
3.10 Pull the handle on
the side of the
power unit box to
STOP
the
machine (Fig E).
COLD STARTING
3.11 Lift rear door.
Open fuel cock if fi tted (Fig F).
3.12 In cold starting situations the engine requires 2cc of engine oil (10w-30) to be applied using oil applicator. The oil should be
inserted into the engine by removing the rubber plug on the priming port, ensure the plug is replaced (Fig G).
3.13 Ensure the Emergency Stop Button is pushed in (Fig H).
3.14 Set the engine speed lever (situatedon the left hand side of engine) to the run position (Fig I).
3.15 Pull out the recoil starting handle tothe point where you feel a strongresistance, then return back theinstall position. Push over
the decompression lever (top right hand side of engine) this will return automatically when the recoil handle is pulled for
the second time.
3.16 Apply both hands to the recoil starting handle and pull briskly, if engine does not start repeat from 3.15.
-
DO NOT operate with rear door open.
WARM STARTING
3.17 Repeat process above from 3.14.
4.
LISTER PETTER : CRANK HANDLE START
Operating Instructions
GB
-
Caution should be taken when starting unit, always use Anti-Kick Back Starting Handle.
-
Ensure handle is correctly engaged in crank barrel (Fig J) before cranking engine.
-
Ensure Oil & Fuel levels are checked daily before starting engine.
-
Ensure rear door stay is correctly engaged before working in power unit area.
-
Keep rear door closed when mixer is running.
4 STOPPING
4.1 Open rear door and move Start / Stop lever to the STOP position (Fig L).
COLD STARTING
4.2 Lift rear door.
4.3 Lift Safety Button up, locate Starting Handle in crank barrel and turn until handle engages (Fig J).
4.4 Engage Start / Stop lever into START position (Fig K).
4.5 Push decompression lever into vertical position and hold (Fig L).
4.6 Crank the engine as fast as possible and move the de-compressor lever into the running position whilst continuing to crank briskly
until the engine starts.
4.7 Once the engine starts remove handle and place back in storage, then move Start/Stop lever into the RUN position(Fig M).
WARM STARTING
4.8 Follow the above instructions from 2.2 to 2.6, however start engine with the Start / Stop lever in the RUN position.
EMERGENCY STOP
4.9 Pull handle on top of power unit box (Fig O).
K
M
O
J
L
N
G
H
I