Instruction of Using Our Products

Instruction of Using Our Products

1. Switch on the power supply
2. Turn on the cold/hot water switch, and adjust to the suitable temperature. Use the switch 
    to choose the faucet or handheld shower to let water in.
3. Don't press the water pump switch unless the water level in the bathtub reach to or 
    higher than the jets position.
4. Use air regulator to adjust the massage power.
5. Rotate the handheld shower to adjust the massage effection.
6. Light turns on and changes automatically when you turn on the pump, and turns off when
    you turn off the pump.

7. Press pneumatic switch, turn off the pumps, and drain the water after use. Then turn off 

  the power supply.

Usage 

Cleaning & Maintenance

1. Use general liquid detergent and soft cloth for daily cleaning. Don't use detergent that 
    with acetone or ammonia. Disinfector with formic acid and formaldehyde is forbidden 
    during disinfection.
2. If there is scratch on the bathtub surface, use 2000# waterproof abrasive paper to 
    polish it and lay toothpaste on. Then use soft cloth to furbish it.
3. Scale deposit can be wiped off with warm citric acid or vinegar by a soft cloth.
4. Screw off the Water Circulation and jets for cleaning when plug up by litter, such as hair
5. Frequent cleaning is not necessary for the parts gilded and silver-gilt
6. Don't clean the tub with hard or coarse material to avoid any scratches; and don't clean 
    the tub by detergent with chemical menstruum to avoid any damages.
7. Be sure to drain off the water and disconnect the power supply after use
8. Don't hit and score the bathtub by hard or keen-edged material. And don't touch the 
    bathtub by cigarette end or heat source that over 70

9. Water massage system cleaning: fill the bathtub with 40

 hot water, and add 

    detergent(2g/L). Then run the water massage system for 5 minutes. After that, stop the 
    pump and drain the water. Fill the bathtub with cold water, and run the water massage 
    system for 3 minutes. Clean the bathtub after stopping the pump and draining off the 
    water.

1. The installation should be carried out by a qualified technician, and should be according 
    to the manual.
2. The appliance electric parameter should be tally with the National Safety Standard. And 
    there should be creepage protector on the power supply. Make sure the ground wire is 
    safe. Don't touch the switch, electrical outlet and plug with water.
3. Don't use overheated water. Put cold water first, then hot water. Don't run the appliance 
    until the water level is higher than the jets.
4. The rated voltage of this appliance is 220V. Don't run it when the voltage is over 235V 
    or under 190V.
5. Disconnect the power supply after use
6. Don't take a bath for a long time. Recommended time: less than 30 minutes
7. Please restart the appliance for occasional system halt
8. If the supply cord is damaged, it must be replaced by the manufacturer, its service 
    gent or similarly qualified persons in order to avoid a hazard.
9. This manual is attached with the product. Before installation, please read it carefully. All 
    he installation and use should conform to this manual, to avoid damage or other accident.

 Precautions

Caution:

1. When the bathtub can't work, please check according to the troubleshooting list. If you can’t judge

    the reason or unable to repair it, please contact us. 
2. To insure the customers' safety, the installation should be carried out by a qualified technician. 
    Please use eligible creepage protector. The ground wire should be well connected to the ground.

Troubleshooting

Trouble

Possible Reason

Try this to solve

Water pump 

Don't work.

Power supply is not well connected, 

the leakage protector disconnect .

Turn on the power supply, and connect 

the leakage protector .
Clean the water pump impeller.

Water pump impeller was stuck 

by sundries.

Press the water pump switch.

The water pump switch is off.

Plug the power supply in.

Power supply plug don't insert or no 

enough power supply.

Repair or replace the water pump.

Water pump trouble.

Massage power 

can't be adjusted.

Voltage problem.

Check voltage.

Adjust switch is off or has problem.

Water Circulation is blocked.

Check, replace the switch.

Clean the water circulation.

Bathtub don't 

stand horizontally.

Adjustable foot is not well-adjusted.

Adjust the Adjustable foot.

Water leakage.

Obturating ring is not good.

Replace the obturating ring.

Nut is loose.
Connect part is not well connected.

Screw down the nut.