BF Apartment Station Digital Entry System
PD
–166 Issue 1
Installation and Operating Manual
Page 20 of 48
ACOD
– Primary Access Code
Main code to open the door. Applies whenever the display indicates [Code]. The Trades
mode (TRAD) needs to be set to „Code‟ or „Trade‟ as per the table below.
The code must be 4 digits and no letters, leading 0 is OK (e.g. [0246]).
TCOD
– Secondary Access Code or Tradesmen’s Code
Secondary „tradesmen‟s‟ code to open the door. Valid only when the display indicates
[Code] and the time clock selects the Trade option as per the table below.
The code must be 4 digits and no letters, leading 0 is OK (e.g. [0137]).
LTIM
– Lock Release Operating Time
Door unlocked duration. Range 1 to 99 seconds. Only the last 2 displayed digits are
used. A value of 0 will default to 1 second and a value containing alpha characters will
default to 3 seconds.
LOCK
– Lock Type
[Secr]
= Fail secure lock: - Requires alternate mechanical means, key or thumb-turn to
open on power failure.
[Safe]
= Fail safe lock: - Lock opens on power failure.
CAM2
– Second Camera Present?
[No]
= Only 1 camera,
[Yes]
= Second camera present.
TRAD
– Door Button Trades Mode
„None‟ = No function; pressing the
door
button is ignored.
„Door‟ = Pressing the
door
button opens the door.
„Code‟ = Pressing the
door
button prompts for the [ACOD] access code to open the
door.
„Trade‟ = Pressing the
door
button prompts for either the [ACOD] or [TCOD] code to
open the door
DMON
– Door Status Switch
[Owc]
= Contacts open when door is closed: - The default allows for no switch fitted.
[Cwc]
= Contacts closed when door is closed: - Standard normally closed switch.
RECP
– Reception Phone Address
The
reception
button is used to call a reception desk or similar. The number is that of the
called phone. The default is [9898] which is unlikely to be used by a flat.
Setting
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
Time Clock Off None None None None Code
Code
Code Trade Trade Door
Time Clock On None Door Code Trade Trade
Door
Code Trade Door Door