background image

CONTROL  UNIT 

55A 

55B 

29 

1 9  

12 

(/)-

28 

(/)-

19 

0-

13 

(/)-

21 

(/)-

30 

13 

(/)-

(/)-

I

(/)-

0--

14 

16 

0-

34 

20 

0-

33 

29 

24 

0-

0-

0-

1 5  

0-

1

32 

0-

35 

0-

27 

0-

36 

0-

NOTES: 

PART 

OF 

CO

N

NE

CT

O

R  CABLE 

(NOT 

A75A 

(G-Wl  B I NDER 

STRAP 

OR  AIOOO 

IS-WI  BINDER 

(

N

O

TE  2) 

CONN 

(Y-O) 

DRY 

GRO 

(NOTE  6) 

R I 

(G-Il) 

Tl 

(

\1-G

PI 

(BL-R) 

P

(BR-R) 

P4 

(R-BR) 

(0-BK) 

AG 

(

B

K-0

Ml 

(S

-

B

K

M2 

(

B

K-

S

(G-Y) 

SP2 

(BR-Y) 

S

P

(Y-BR) 

3) 

B-BI 

(S-Y) 

R-R I 

(Y

-

S

B-BI 

TO  KTU  FOR 

R-R I 

COMMON  S 

C

O

N

T

R

O

B L  

T O  BUSY 

LAMP  CO

NTR

OLL

E

TFI 

T

F

2012B  IMD) 

OR 

2012D 

TRNSF 

42 

28 

34 

12 

37 

15 

40 

18 

19 

44 

20 

45 

BY 

ISS  5,  SECTION  512-620-440 

PART 

OF 

0 120C 

630C ,  630D ,  631C  OR  631D 

MTG  CORD 

(G-W)  B I NDER 

TELEPHONE  SET 

(PARTIAL) 

OR  PART  OF  0200F 

MTG  CORD 

IS-WI  B I N DER 

667 

(

N

O

T

E  5) 

TYPE 

TEL  SET  TERM, 

TB 

ID 

KEY 

TRMTR 

(TABLE 

A) 

PLUG 

ID 

OR 

PLUG 

ID 

630C 

6300 

OR 

Jl 

(Y-O) 

(0-Y) 

OR 

Jl 

631C 

6

3

1

37 

(G-Il) 

13 

(w-G) 

38 

RR 

RR 

(BL-R) 

(BR-R) 

\1 

II 

1 5  

(R-BR) 

40 

--0 

(0-BK) 

(BK-0) 

41 

(S-BK) 

(BK-S) 

42 

(G-Y) 

18 

(BR-Y) 

(Y-BR) 

USE 

SPARE  TERMINALS 

OR 

D-

I 61488  CONNECTORS 

(

S

-Y) 

:] 

(NOTE 

4) 

(Y-S) 

���� 

S

P

EA

K

ER

P

H

ON

(

G

760A 

(R) 

LO

U

D

S

P

E

A

KE

I,  IF  CONTROL  UNIT 

IS  LOCATED 

AT 

KEY  EQUIPMENT, 

USE  (G-Il)  BINDER  GROUP  OF  A75A 

CONNECTOR  CABLE  (630-TYPE  SET) 

OR  (S-\1)  BINDER 

GROUP 

OF 

AIOOD 

CONNECTOR  CABLE  (631-TYPE  S

ET

FOR  SPEAKERPHONE  LEADS;  FOR  OTHER 

L

OC

A

TIONS

CONNECT  TO  CONTROL  UNIT  USING 

A25-TYPE  CONNECTOR  CABLE. 

2.  ADD  STRAP 

FOR 

STATION  BUSY  LAMP  CONTROLLED  BY  SPEAKERPHONE. 

3.  CONNECT  SPI  LEAD 

TO 

TERMINAL  30  (ON 

55B) 

O

TERMINAL  24  (ON  55A) 

\/HEN  RE

D

U

C

r

LOUDSPEAKER 

VOLUME  IS  DESIRED. 

4. 

CONNECT  (S-Y)  (Y-S)  TO 

BUZZER 

O

RINGER  (IN 

PLACE  OF 

EXISTING  LEADS)  TO 

PROVIDE  AUTOMATIC  CUTOFF 

OF  COMMON 

AUDIBLE  SIGNAL 

OUR I 

NG  SPEAKERPHONE  OPERATION. 

5.  DI20C 

MTG  CORD  AND  A75A 

CONN  CABLE  USED 

\liTH  630-TYPE  TELEPHONE 

S

E

AND  D200F 

MTG 

CORD  AND  AIOOD  CONN  CABLE 

USED  \liTH 

631-TYPE  TELEPHONE  SET. 

6.  CONNECT LOCAL  GROUND. 

INSULATED  AND  STORED 

Fig.  3-.630C,  6300,  631C,  or  6310  Telephone  Set,  Connections. 

SSP S12-620-440-iOS_1979-07.QS.jpg  Scanned by  frank Harrell, (Cowboy  frank) Castle Rock, Colorado  Feb  16,2012  23:00:31 

Page  5 

Summary of Contents for 1630 Series

Page 1: ... 2630D MD and 2631D MD Telephone Sets 2 02 Convert as follows a Remove telephone set faceplate and housing See Section 502 600 100 for procedures b Remove key unit or apparatus blank in right hand module position third or fifth module and plug in a 667B MD transmitter ordered separately c Connect spade tipped leads of transmitter as shown in Fig 1 2 3 5 and Table A d Install housing See Section 50...

Page 2: ... unit 3 05 To retain the maximum number of keys in the CALL DIRECTOR telephone sets and still have speakerphone feature a 666A MD or 666B MD transmitter and 760A MD loudspeaker may be installed as adjuncts to the telephone set Spare leads and hold key lamp leads from the first module are used to supply the external speakerphone function When control unit and telephone set are at same location an a...

Page 3: ...EPHONE SETS PARTIAL 667 TEL SET TYPE TERM 630A KEY TRMTR OR 6306 TB PLUG m TABLE A G IBR n 4 37 r I 13 iiR 38 14 _ II 15 BB 40 G 41 Ll 16 _ 42 _ 17 _ 16 _ NOTE 4 USE SPARE TERMINALS OR D 161486 CONNECTORS c f p G ll 760A LOUDSPEAKER R I If CONTROL UNIT IS LOCATED AT KEY EQUIPMENT EXTEND SPEAKERPHONE CONNECTIONS THROUGH APPROPRIATE LEADS IN 0 G AND BR BINDER GROUPS Or AIOOA MD OR G 1 BINDER GROUP O...

Page 4: ...AL TEL SET TERM 667 631A OR 631B KEY TYPE SEE TABLE A T8 1r PLUG TRMTR 8R1 37 r 1 I I I I I3 I 1 X 38 1 I U 14 j I IS w _ _ I 40 _ _ I I 3 I 41 I I 1 6 Ll I j I 42 j I 17 j I 18 __j NOTE 4 c v USE SPARE TERMINALS OR D 161488 CONNECTORS b G 760A R LOUDSPEAKER I If CONTROL UNIT IS LOCATED AT KEY EQUIPM NT EXTEND SPEAKERPHONE CONNECTIONS THROUGH APPROPRIATE LEADS IN G AND BR BINDER GROUP Of AIOOA MD ...

Page 5: ...I2 U 0 I I I I 0 BK I 16 L _ 9 I I l BK 0 I 5 41 t 0 I S BK I n H I BK S I 42 I G Y I I I 18 Lf I L___ I BR Y I Y BR I USE SPARE TERMINALS OR D I61488 CONNECTORS I I S Y NOTE 4 I Y S SPEAKERPHONE G 760A R LOUDSPEAKER I IF CONTROL UNIT IS LOCATED AT KEY EQUIPMENT USE G Il BINDER GROUP OF A75A CONNECTOR CABLE 630 TYPE SET OR S 1 BINDER GROUP OF AIOOD CONNECTOR CABLE 631 TYPE SET FOR SPEAKERPHONE LEA...

Page 6: ...R 0 S BK 47 BK S 48 0 4 NOTE I 0 s Y Y S 19 0 NOTE 2 0 BK 51 BK 0 52 I WHEN CONTROL UNIT IS USED TO CUT Off RINGER OR BUZZER IN SET CONN CT THESE LEADS AS SHOWH INSULATE AND STORE 15 Y AND Y Sl FROM BLI BINDER 2 INSULATE AND STORE 0 BKI AND BK 0 TO SRI PLUG 3 STRAP 26 TO 29 55A OR 21 TO 19 558 WHEN BUSY LAMP IS CONTROLLED BY SPEAKERPHONE USE DC LAMP OR BUSY LAMP CONTROL CIRCUIT PER S0 69403 0I 4 C...

Page 7: ...10 I I 15 Y G I I I I 40 G Y 12 I I 41 0 Y I I I I Y O I I I I 0 V I I 18 I I 17 I I 42 I I 14 I I 37 I I 16 760A LOUDSPEAKER NOTE I INSIDE 20128 MDI WIRE NOTES OR20120 TRNSF I IF LOUDSPEAKER IS LOCATED MO FROM CONTROL UNIT EXTEND MO RE THAN MOUNTING CORD LENGTH UNTING CORD USING INSIDE liRE AND D 161488 CONNECTORS OR SUITABLE CONNECTING BLOCK 2 IF REDUCED LOUDSPEAKER VOLUME IS DESIRED CONNECT SPI...

Page 8: ... 0 J TO KTU SIGNAL CONTROL ___ _ o _ __ J____ ___ 5 0 2 1 _ T _ E _ 2 7 A 0 BK BK 0 TO BUSY LAMP CONTROLLED BY 20128 MDI OR 20120 TRNSF LJ BK 0 __ __ ___ LOUDSP AKER NOTES SPEAKERPHONE NOTE 3 I WHEN CONTROL UNIT IS USED TO CUT orr RINGER OR BUZZER IN SET CONNECT THESE LEADS AS SHO IN INSULATE AND STORE IS YI AND IY SJrROM IBLI Bl NDER 2 INSULATE AND STORE 10 BKI AND IBK 01 TO IBRI PLUG 3 STRAP 26 ...

Page 9: ...I NOTES CONNECTIONS SHOWN ARE USED WHEN CONTROL UNIT IS LOCATED NEAR TEL SET IF CLOSE ENOUGH CONNECTING BLOCK MAY BE ELIMINATED BY TERMINATING CORDS FROM TEL SET TRMTR AND LOUDSPEAKER DIRECTLY TO CONTROL UNIT WHEN CONTROL UNIT IS LOCATED AT EQUIP o4ENT EXTEND SPEAKERPHONE LEADS THROUGH CONNECTOR CABLE 2 INSULATE AND STORE SPARE CONDUCTORS IN DIOR AND TIIA CORDS 3 EITHER THE 55B OR 55A CONTROL UNIT...

Page 10: ... LAMP 760A CONTROLLED BY LOUDSPEAKER SPEAKERPHONE G R2FK CORD o IR I NOTES I CONNECTIONS SHOIIN ARE USED HEN CONTROL UNIT IS LOCATED NEAR TEL SET IF CLOSE ENOUGH CONNECTING BLOCK MAY BE ELIMINATED BY TERMINATING CORDS FROM TEL SET TRMTR AND LOUDSPEAKER DIRECTLy TO CONTROL UNIT HEN CONTROL UNIT IS LOCATED AT EQUIPMENT EXTEND SPEAKERPHONE LEADS THROUGH CONNECTOR CABLE 2 INSULATE AND STORE SPARE COND...

Page 11: ...NE R2FK CORD G r IR I NOTE S CONNECT I ONS SHO IN ARE USED HEN CONTROL UN I T IS LOCATED NEAR TEL SET I F CLOSE ENOUGH CONNECT I NG BLOCK MAY BE E L I M I NATED BY TERM IHAT I NG CORDS FROM TEL SET TRMTR AND LOUDSPEAKER D I RECTLY TO CONTROL U N I T HEN CONTROL UN I T IS LOCATED AT EQU I PMENT EXTEND SPEAKERPHONE LEADS THROUGH CONNECTOR CABLE 2 I NSULATE AND STORE SPARE CONDUCTORS I N D I OR AND T...

Page 12: ...SPEAKER SPEAKERPHONE G R2FK CORD I R I NOTES I CONNECT I ONS SHOWN ARE USED WHEN CONTROL UN I T IS LOCATED NEAR TEL SET I r CLOSE ENOUGH CONNECT I NG BLOCK MAY BE E L I M I NATED BY TERM I NA T I NG CORDS FROM TEL SET TRMTR AND LOUDSPEAKER D I RECTLY TO CONTROL UN I T WHEN CONTROL UN I T IS LOCATED AT EQUI PMENT EXTEND SPEAKERPHONE LEADS THROUGH CONNECTOR CABLE 2 INSULATE AND STORE CONDUCTORS IN D...

Page 13: ... stored location t Terminal on network FROM TO 46 RRt 44 1 3 39 9 14 4 3 7 Note 6 1 38 30 4 Note 1 Connections shown are used when transmitter is part of telephone set and speakersphone leads are connected through the mounting cord Note 2 When control unit is located near the telephone set an A25B conntctor cable may be plugged into the 3rd mounting cord plug 630DA DAM or 5th plug 631DA DAM and te...

Page 14: ...ed when control unit and apparatus unjt are at same location Leads are in BL binder Note 2 Connect to L2t if busy lamp is also furnished Page 14 14 Pages TABLE F Note 2 Lamp in hold position cannot be supplied due to lack of spare lead conductors SPEAKERPHONE CONNECTIONS USING INTERNAL TRANSMITTER 2630DA DAM OR 2 6 3 1 DA DAM TELEPHONE SET WIRE OR LEAD Y BL BL Y Mtg Y 0 Cord Note 1 0 Y Y G BR BK P...