Plexus 9000 Planning and Engineering Guide
DS3 ATM Network Access Module
Section 130-120-800
Issue 1, April 23, 2004
Telica, Inc.
5-195
General Mechanical Representation ................................................5-196
Line Interface Units (LIUs)..............................................................5-200
ATM Port Controller (APC) ............................................................ 5-200
Serializer/Deserializer (SERDES) ...................................................5-200
MLBA and Local Control Circuitry................................................. 5-201
Microprocessor, Memory Bus Controller and Memory...................5-201
Segmentation and Reassembly (SAR) ............................................. 5-201
Clocks and Synchronization............................................................. 5-201
5.18.1 Scope
This section describes the front DS3 ATM Network Access (DNA)
module. It explains the module functions, LED indicators, and connector
interfaces.
The CLEI codes of the modules are as follows:
Part Numbers CLEI
Codes Comments
89-0409-A
BA5AAE0CAA
.
Note:
Shaded part numbers have been “manufacture discontinued,” but
are still supported.
5.18.2
Functional Description
The DNA supports eight channels of ATM over DS-3. It does not support
channelized DS3 networks. The DNA module requires a rear module for
physical interface terminations. This is the same rear module used for
Octal DS3/STS-1 modules. The associated rear module has two (2) BNC
connectors, transmit and receive, per DS-3 totaling sixteen connectors.
The rear protection module is the same as the Octal DS-3 protection
module and does not have any connectors.