9
Technical Specifications
Storage
Storage Conditions
Store the PureAV Battery Backup covered and upright in a cool, dry location
with its battery fully charged. Before storing, charge the PureAV Battery
Backup for at least four hours.
Extended Storage
During extended storage in environments where the ambient temperature is
+5 degrees to +86 degrees F, charge the PureAV Battery Backup’s battery
every six months. During extended storage in environments where the
ambient temperature is +86 degrees F to +113 degrees F, charge the PureAV
Battery Backup’s battery every three months.
Model
AP30800-10
INPUT
Capacity
1200VA/640W
Voltage Range
90-136VAC
Frequency
60Hz (
±
3Hz )
OUTPUT
Voltage
Simulated sine wave,
120VAC
±
8%
Frequency
(On Battery)
60Hz (
±
1Hz )
BATTERY
Backup time
15%-100% load
1.5~40 min.
Typical
Recharge Time
≤
12 hours recover
85% capacity
ENVIRONMENT
Ambient
Operation
0~85% humidity
non-condensing, 0~35°C
CONFORMANCE
Surge
IEEE C62.41
Category A standard
PHYSICAL
Dimension
(W x H x D)
435mm x 88mm x 330mm
Net Weight
14.5kg.
All specifications are subject to change without prior notice.