background image

Pur
eA

B

at

tery 
B

ack
up

7

Installation

To Silence Audible Alarm

There are two ways to disable the audible alarm:

1. 

Set the Alert Sound ON/OFF Switch to the OFF position. When in 
the OFF position, the audible alarm will not sound when the PureAV 
Battery Backup is in the backup mode.

2. 

While in battery-backup mode, push the “ON/OFF/TEST” button less 
than 1.5 seconds to silence the audible alarm. (This does not work if the 
PureAV Battery Backup is under low-battery or overload condition.)

All equipment must be turned off prior to hardware installation.

Connect The Phone/Fax/Modem/Lines 

Connect a single phone/fax/modem line into the surge-protected sockets 
on the back of the PureAV Battery Backup. The RJ11 modular sockets 
accept standard single-line telephone connections. The connection will 
require another length of telephone cable, which is supplied.

Note!

 This connection is optional but highly suggested as phone/fax/

modem lines often carry dangerous surges and spikes. The PureAV Battery 
Backup works properly without a phone/fax/modem connection.

Caution!

 The phone/fax/modem protection feature could be rendered 

inoperable if improperly installed. Make sure that the telephone line from 
the wall is plugged into the connector marked “IN”, and the device to be 
protected is plugged into the connector marked “ OUT”.

Connect The Network Line 

Connect the network line from the wall to the connector marked “IN”, 
then connect the device (Ethernet card) to be protected to the connector 
marked “OUT”.

Connect Audio Video Coaxial Cable 

Connect a modular coaxial cable between the cable wall outlet and the 
surge protector jack marked “IN”. Connect another coaxial cable between 
the surge protector jack marked “OUT” and the cable equipment or cable 
modem being protected.

*All equipment must be turned off prior to hardware installation.

Telephone Socket

Phone/Fax/Modem

Summary of Contents for PureAV AP30800-10

Page 1: ...Home Theater Battery Backup with AVR Technology User Manual Clear Picture Clean Sound AP30800 10...

Page 2: ...Page Introduction 2 Package Contents 2 PureAV Battery Backup Features and Functions 3 Alarms 4 Product Features 5 Installation 6 7 Troubleshooting 8 Technical Specifications 9 Storage 9 Belkin Connect...

Page 3: ...power conditioning while ensuring that you experience the clearest picture and cleanest sound directly from the source Please save this manual It contains important operating instructions and warranty...

Page 4: ...rload or short circuit condition Flashing Yellow Battery output is drawing more power than the Battery Backup can provide REPLACE BATTERY Red LED Solid Red Battery is weak or bad the battery needs to...

Page 5: ...is in battery backup mode and the battery s energy begins to run low the PureAV Battery Backup will beep rapidly until it shuts down from a depleted battery or returns to online normal operation Overl...

Page 6: ...power strips into the battery backup outlets Note During the AVR Mode the total load that you will be placing on the battery backup outlets should not exceed 85 of the unit s capacity C Phone Protect...

Page 7: ...sing and holding the On Off Test button for approximately two seconds until the green ON LINE light comes on Turning Off The PureAV Battery Backup Turn off the PureAV Battery Backup by pressing and ho...

Page 8: ...e cable which is supplied Note This connection is optional but highly suggested as phone fax modem lines often carry dangerous surges and spikes The PureAV Battery Backup works properly without a phon...

Page 9: ...loose Re plug the power cord AC breaker is burned out or tripped Replace or reset the breaker AC utility voltage is too high or too low or there is a blackout Normal condition Backup time too short B...

Page 10: ...orage in environments where the ambient temperature is 86 degrees F to 113 degrees F charge the PureAV Battery Backup s battery every three months Model AP30800 10 INPUT Capacity 1200VA 640W Voltage R...

Page 11: ...to the fair market value of the damaged equipment or the original purchase price of the equipment whichever is less up to the maximum amount set forth below Model AP30800 10 Up to a maximum of 500 00...

Page 12: ...st damage to properly connected equipment where Belkin Corporation has determined in its sole discretion that the damage resulted from an Occurrence and does not protect against acts of God other than...

Page 13: ...nut St Compton CA 90220 Attn Technical Support or call 310 898 1100 extension 2263 within 15 days of the Occurrence Be prepared to provide the following information a The part number of the PureAV Bat...

Page 14: ...xpressly approved by the party responsible for compliance could void the user s authority to operate this equipment SAFETY INFORMATION CAUTION Internal battery voltage is 12VDC The unit is intended fo...

Page 15: ...PureAV Battery Backup 14...

Page 16: ...35 2000 Fax 44 0 1933 31 2000 Belkin B V Boeing Avenue 333 1119 PH Schiphol Rijk The Netherlands Tel 31 0 20 654 7300 Fax 31 0 20 654 7349 Belkin Ltd 7 Bowen Crescent West Gosford NSW 2250 Australia...

Reviews: