background image

F6H350-SER

F6H500-SER

F6H650-SER

Capacity

350

500

650

Max Load

190 W

300 W

360 W

Voltage Range

Frequency

Voltage (On battery)

Frequency (On battery)

Voltage Regulation 

(AVR)

Transfer Time

Spike Protection

EMI/RFI Filter

Overload Protection

Unit Input

Telecommunication 

Protection

Short Circuit

Voltage / Amps

12V / 5Ah

12V / 5Ah

12V / 7Ah

Type

Typical Recharge Time

Protection

Battery Run Time

Upto 15 minutes

Upto 28 minutes

Upto 35 minutes

Battery Backup

Battery Low

Overload 

Fault

Battery Test

Ambient Operation

Audible Noise

Weight (lbs)

8.81

10.14

12.34

Dimension (inches) W 

x D x H

AC Power On

Power Off

Cold Start (Turns DC 

Power On)

Buzzer Silence (On 

Battery Mode)

Alarm

Environment

Communication Port

Press less than 1.5 sec.

Press and hold longer than 2 sec.

Press and hold longer than 2 sec.

Press and hold longer than 2 sec.

Compliance

Physical

RS232 Serial Port

UL/cUL, EMI, IEC 1000-4-2 Level 3, IEC 1000-4-4 Level 2, IEC 1000-4-5 Level 3

9.84 x 6.61 x 3.15

0 ~ 85% Relative Humidity (Non-condensing); 0 ~ 35º C Operation Temp.

<40dBA at 1 meter

Automatic self discharge protection, replace battery indicator LED

Flashing Red LED and Audible Alarm 10 second continuous

Solid Red LED Light

Slow beeping sound (about 15 second intervals)

UPS shuts down

Sealed, maintenance free lead acid

<8 Hours

Model

Input

Protection  and 

Filtering

Output

Battery

Meets FCC Class B

UPS Low voltage switch to high voltage switch to battery: 105 ~ 135 ±3 Vac

Front Panel 

Switch

105 ~ 135 Vac

60Hz  ±1Hz

60Hz  ±1Hz

Simulated Sine Wave, 120Vac ±10%

Breaker for overload and short circuit protection

1 In, 2 Out Single Line (2 Wire, RJ11) jack s

No AVR

N/A

510 Joules

Home Series UPS-Serial